Saswell SAS6000UTK-7-WIFI Скачать руководство пользователя страница 22

23

.

Audible beeper option

Parameter options:(YES,NO)
YES: Thermostat will keep when any button touched                 
NO  : Thermostat will turn off the voice

Factory default:YES

24

.

Keypad lockout option

Parameter options:(unL,PAL,FUL)
unL: Unlock .All keys are available, screen is unlocked        
PAL: Partially locked. All key functions are locked except “

SYSTEM

” key, temperature “

UP

” and

        “

DOWN

”  keys and the “

CANCEL

” key. Enter configuration setup to unlock the screen

FUL: Fully locked.Screen is fully locked except “SYSTEM” key
         Enter Configuration setup to unlock the screen

Factory default:unL

25

.

Changeover valve output option

Parameter options:(o,b)
o: Said in heating mode, O/B relay will be output, Heating is effective
b: Said in Cooling mode, O/B relay will be output, Cooling is effective           

Factory default:o

39

40

In case of difficulty

How to install?
Please check user instruction on 
Page 7.

How do I open the back cover?

Grasp top and bottom of wallplate 
andpull to remove from thermostats.

Support systems:
Single Stage Gas, Oil, Electric Single 
Stage, Heat Pump.

Does the thermostat need a C wire?

Yes, it has a C - line

Will this work with 2 wire line volt 
system?
Yes

Why does the temperature display
differ from the actual temperature?
The difference can be from tolerance
of temperature components, location,
Indoor air flow condition.    

Does this have a separate " heat, 
cool, off" switch?

Yes, it has a switch for this function,
 please find Page 18.

Does it work with Amazon echo/alexa
or the new google home?

No.

Can you reset this thermostat from 
any location?

Yes, can resume to factory default 
setting, please find Page 22.

We provided several FAQs. 
Please follow the guide and make reference to the manual. 

Содержание SAS6000UTK-7-WIFI

Страница 1: ...info saswell com Factory 3 4 6 F Building A East 8th Region shangxueIndustry Science Park Buji town ShenzhenCity Guangdong China SAS6000UTK 7 WIFI SAS6000UTK 7 WIFI Installation and Operation Instruc...

Страница 2: ...stat installation 07 The wiring diagram 08 Alternate wiring conventional system 09 Alternate wiring for heat pumps only 11 Batteries installation 12 Program setting 20 Permanent hold override 24 Vacat...

Страница 3: ...s SAS6000UTK 7 WIFI thermostat wallplate attached to back Wire labels Wall anchors and mounting screws 2 each Instruction for Installation and Operation 01 02 SAS6000UTK 7 WIFI Installation Operation...

Страница 4: ...wires attached when you remove cover and thermostat 1 Use a screwdriver to disconnect wires one by one As you disconnect each wire wrap it with the label matching the letter on your old thermostat Adh...

Страница 5: ...op and bottom of wallplate and pull to remove from thermostat Wallplate Pull wires through wallplate Level wallplate if desired Mark positions of both screw holes 4 Mark wallplate mounting position 1...

Страница 6: ...and snap into place The Wiring Diagram Insert wires then tighten screws L RH RC G AUX E S2 S1 Y C O B Y2 L RH RC G W W2 S2 S1 Y C Y2 1 Match each labeled wire with same letter on terminal Use HEAT PU...

Страница 7: ...ith electrical tape and do not connect them 1H 1C System RC RH W Y G C W2 Y2 Rc R W Y G C W2 Y2 2 3 2 Remove metal jumper connecting RH and RC only if you must connect both RH and RC wires If your old...

Страница 8: ...right and connect to terminal as shown here see notes below 2 3 3 5 5 4 6 6 RH S1 S2 S1 S2 Remote Sensor Remote Sensor Compressor contactor Fan relay 24v common Changeover valve Equipment monitor Eme...

Страница 9: ...the o position before installing removing cleaning or servicing this thermostat Read all of the information in this manual before installing this thermostat Only a professional contractor should insta...

Страница 10: ...cluding Single stage Multi stage And Heat Pump Up to 3 stage heat 2 stage cool with Aux Or Emergency heat Large LCD display with backlight continuous backlight option Menu driven programming Fan switc...

Страница 11: ...ed on the same day When SYSTEM button set to AUTO the thermostat automatically select heating or cooling depending on the indoor temperature 2 Press the to save and exit DONE 17 18 COOL Thermostat con...

Страница 12: ...he fan only when the heating or cooling system is on ON Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning 2 Press to enter set program SET SC...

Страница 13: ...eturn Home Evening 17 00 WAKE SLEEP LEAVE RETURN 6 Press or to adjust the time for program period start WAKE SLEEP LEAVE RETURN 9 After you have complete the settings press to con rm and exit DONE 8 P...

Страница 14: ...ek 1 In Heating lower temperatures will save energy 2 In Cooling higher temperatures will save energy 3 If you plan on using Auto Changeover set the heating temperature below the cooling set temperatu...

Страница 15: ...the vacation hold program is completed if you want to resume the schedule earlier please press RUN SCHED This feature can suspend the program schedule for extended period of days RUN SCHED This functi...

Страница 16: ...o you can clean the screen without changing any setting 4 After 30 seconds press to DONE resume normal operation or press again if you CLEAN DISPLAY require more time for cleaning CLERN CLEANDISPLAY D...

Страница 17: ...enu 4 Press the for display other menu OTHER 5 Press the for entering CONFIG con guration menu 6 Press to select con guration parameter setting 7 Press for changing to NEXT STEP the next menu item set...

Страница 18: ...lt 2H This option apply only to HP1 or HP2 setting in system type option 4 Manual Autochangeover option Parameter options 0 1 0 Manual changeover 1 Auto changeover Factory default 0 5 Auto changeover...

Страница 19: ...ow set point Factory default FA This option apply only to HP1 or HP2 setting in system type option 10 Compressor lockout delay option Parameter options 0 5 To protect the compressor from short cycling...

Страница 20: ...nd stage heating will activate 2 5 below rst stage heating Factory default 7 16 Sceond stage cooling rate option Parameter options FA SL FA Fast second stage cooling rate Second stage cooling will act...

Страница 21: ...UF It means cancel the function Factory default UF The thermostat will display the Chg UV when UV time 400 days has expired 21 Heat pump compressor lockout option Parameter options 0 15 20 25 30 35 4...

Страница 22: ...e output Cooling is e ective Factory default o 39 40 In case of di culty How to install Please check user instruction on Page 7 How do I open the back cover Grasp top and bottom of wallplate andpull t...

Страница 23: ...ting program c check the con guration table and con rm the value of the Item 14 PRGM to be 7 Page 35 in operation manual How do I open the back cover Grasp top and button of wall plate and pull to rem...

Страница 24: ...FI frequency 2 4 Ghz or 5Ghz This thermostat only work for 2 4 Ghz Before install adjust your router to 2 4Ghz Insert router name and account get failed The router password should have not special cha...

Отзывы: