background image

§

  Remove the right and left mounting 

aids as follows: 

Unscrew the four M8 bolts as shown 

(wrench size: 13).

§

  Hook the drive-on ramp onto the 

right and left retainers.

  Transporting the IF (Option T7)

§

  Make sure there is no load on the 

scale.

§

  Remove the drive-on ramp from the 

front of the scale.

$

  Make sure to observe the safety 

instructions.

§

  Remove the threaded caps from  

the four threaded fasteners and keep 

them in a safe place.

$

  Lubricate the threaded fasteners  

regularly, so that the caps can  

be removed and the hand cranks 

attached at any time without  

difficulty.

§

  Attach the two hand cranks to  

the two threaded fasteners at the 

front of the scale.

§

  Turn the cranks clockwise to lower 

the transport rollers.

$

  Repeat this procedure for the  

two rear rollers.

  Important: 

Make sure there is no load on the 

platform before you move it.

§

  The scale can now be moved into  

the desired position.

§

  If available, fasten the towing bar 

(optional) as shown. 

§

  The scale can now be pulled into  

the desired position.

$

  This procedure is useful, for exam-

ple, for cleaning the surface beneath 

the scale at the place of installation.

§

  Return the weighing platform to  

the place of installation and retract 

the rollers.

§

  Remove the hand crank.

§

  Replace the four threaded caps.

§

  Fasten the drive-on ramp to the  

front of the scale.

$

  Make sure to observe the safety 

instructions.

7

Содержание IF CE Series

Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...Installation and Operating Instructions Sartorius IF Standard and IF CE with T8 Lifting Mechanism Flat bed Scale 98648 012 37 98648 012 37...

Страница 3: ...arf die W gebr cken mit klappbarer Last platte ffnen schlie en Sicherstellen dass sich keine Personen im Gefahrenbereich vor oder un ter der aufgeklappten Lastplatte befinden Bedienung nur von der rec...

Страница 4: ...fac turer s warranty If the equipment housing is opened by anyone other than per sons authorized by Sartorius this will negate its con for mity with regulations governing its use and result in forfeit...

Страница 5: ...Make sure there are no cables or other objects exerting force on the load plate Avoid generating static electricity Using the IF CE in Legal Metrology in the EU The type approval certificate for veri...

Страница 6: ...t the scale evenly Move the scale to the place of instal lation Warning Danger of personal injury Do not stand or move beneath the scale while it is suspended Make sure to read and follow the safety i...

Страница 7: ...s slide into the side plate and secure the platform in the vertical position The surface under the platform can now be cleaned easily Install the pneumatic springs right and left as shown in the illus...

Страница 8: ...the two hand cranks to the two threaded fasteners at the front of the scale Turn the cranks clockwise to lower the transport rollers Repeat this procedure for the two rear rollers Important Make sure...

Страница 9: ...e sleeve and the side plate Screw the left base plate 7 and the left side plate 1 together and the right base plate 8 and right side plate 2 together using screw M12 65 and nut M12 Place the lift up m...

Страница 10: ...platform so that the back load bearing feet are in the fastening plates of the transverse strut and align Screw the four downholders 9 to the side plates 1 and 2 using M6 20 The platform and the downh...

Страница 11: ...plastic impact cap 19 to protect the flooring When lifting up and down for the first time ensure that the measurement cable is not damaged or squashed Mount the grips to the scale platform Drill holes...

Страница 12: ...voltage black brown blue Signal Output signal white green Signal Output signal red pink gray Sense Sense line green white Sense Sense line gray black Ground Shield Shield Shield Diagram Showing Loadi...

Страница 13: ...pacities 59 models 3000 e 2 3000 e Cl III depends on model 15 000 d 30 000 d Material surface finishing AISI 304 or AISI 316 Ti stainless steel brushed or electropolished IP67 IP65 rating Stainless st...

Страница 14: ...F is no longer war ranted i e If there is visible damage to the connecting cable If the device no longer functions properly If the equipment has been stored for a relatively long period under unfa vor...

Страница 15: ...m to the floor Floor mounting set YFP01I Columns can be manufactured to order on request Dimensions Designation GG IG II LG LI LL NL NN RN RR WR D mm 600 800 800 1 000 1 000 1 000 1 250 1 250 1 500 1...

Страница 16: ...interference 73 23 EEC Electrical equipment designed for use within certain voltage limits as amended by 93 68 EEC Applicable European Standards EN 60950 Safety of information technology equipment inc...

Страница 17: ...16...

Страница 18: ...17...

Страница 19: ...18...

Страница 20: ...19...

Страница 21: ...20...

Страница 22: ...21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...25...

Страница 27: ...26...

Страница 28: ...27...

Страница 29: ...he prior writ ten permission of Sartorius All rights reserved The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius reserves the...

Отзывы: