11/30/17
1-800-810-WIRE • www.sargentlock.com • A7861C 3
Copyright © 2017, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
Profile Series v.G1.5 Mortise Dorm Lock
Features
General Description
The SARGENT Profile Series v.G1.5 Mortise Dorm Lock is designed to prevent residents from being locked
out of their rooms. The resident presents a proximity card and/or pin code, which works as a toggle to unlock
(overriding the deadbolt if thrown) or relock the outside lever. When entering a room, the deadbolt locks the
outside lever. When exiting the room, retracting the deadbolt unlocks the outside lever.
If the outside lever is locked and the deadbolt is not thrown, rotating the inside lever will unlock the outside
lever (via the lockbody’s inside monitor switch).
The resident must present their prox card and/or pin code to relock the door.
It is a self-contained microprocessor-controlled keypad with non-volatile memory. The keypad holds a total
of 100 (LK)/2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) different user codes. User codes
01
and
02
are
utilized for Master and Supervisory Codes, respectively. SARGENT mortise locks are designed with quality
components to provide high security, performance and durability.
This product is operated by six (6) “AA”
alkaline*
batteries.
Specifications
• Latch - Stainless steel
• Deadbolt - Stainless steel
• Guardbolt - Stainless steel, non handed
• Handed - Easily field reversible without
disassembling the lock body
• Case - 12 gauge heavy duty wrought steel
3
4
2
• Outside lever controlled by any combination
of keypad, proximity or RF technology
• Inside lever retracts latch and deadbolt
• Locks furnished for 1-3/4" doors. Can be furnished
for other door sizes upon request.(Consult factory)
• U.L. Listed (3 hr.)
• RF Fob and Proximity Card, Tag, and
Fob are optional
• Operates utilizing any one to six digit code
• Digits may be repeated and codes may
start with zero
• Cylinder override
• Entry of three wrong User Codes disables all
codes for ten seconds. Yellow LED on solid
• Piezo horn can be heard with each keystroke
or turned off by Master or Supervisory Code
• Last 2000 (Except LK) transactions can be
output to PC via DTD/SoloPlus™ Software
• Non-volatile memory
• Motor driven, battery operated
• Battery operated with 6 “AA” Alkaline
• Low battery alert: 4 chirps after code entry
• External remote “Request to Enter”
• Master, Emergency or Supervisory code will
unlock door when low battery has expired
• Programming done at keypad or with a DTD
(Data Transfer Device) using SoloPlus™
software and a Laptop/PC (G1-TA and
G1-TP require software)
SoloPlus™ works with PalmPilot; SofLink™
Plus software not supported with DTD.
!
*To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.