Sargent Passport 1000 PG Скачать руководство пользователя страница 2

      

   A8012E

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved. 

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

10/31/12

1

2

3

4

5

6

                         

Table of Contents

Warning  ........................................................................................ 2
General Description ...................................................................... 3
Hardware Specifications .............................................................. 3
Electronic Specifications .............................................................. 3
Part Breakdown ............................................................................ 4
Rim Type 8877/8878 Exit Device Installation .............................. 8
Mortise Type 8977/8978 Exit Device Installation ...................... 14
Setting up the 

PERSONA LockLink™ 

& Contact Card 

 ................... 20

Lockset Programming  ............................................................... 23
Operational Check ...................................................................... 27

8

7

Warning 

1

FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfe-

rence in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac-

cordance with the instructions, may cause harmful interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one or more of the following measures:
• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications to this unit not expressly approved by the party responsible 
for compliance could void the user’s authority to operate the equipment.

!

Observe precautions for handling electrostatic sensitive devices.

SARGENT Mfg. Co. Passport 1000 locksets utilizing a door position switch (DPS) are not rated for, 

or intended for use in life safety applications.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of 

the opening, and SARGENT Manufacturing makes no representations or warranties concerning what 

such impact may be in any specific situation.  When retrofitting any portion of an existing fire rated 

opening, or specifying and installing a new fire-rated opening, please consult with a code specialist 

or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes 

and ratings.

9

10

Industry Canada: 

Statement: The term “IC:” before the radio certification number only signifies that Industry Canada  

technical specifications were met.
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equip-

ment Regulations. Operation is subject to the following two conditions: (1) this device may not cause 

harmful interference, and (2) this device must accept any interference received, including interfe-

rence that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence cana-

dienne  

causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce  

dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle  

interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

Содержание Passport 1000 PG

Страница 1: ...nufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited PASSPORT1000 Exit Device Installation Instructions PG ...

Страница 2: ...perienced radio TV technician for help Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Observe precautions for handling electrostatic sensitive devices SARGENT Mfg Co Passport 1000 locksets utilizing a door position switch DPS are not rated for or intended for use in life safety applicatio...

Страница 3: ...retracts latch 8977 only Available in ET lever handle designs only Provide Deadbolt override at user specified doors for groups or individuals Connect to an external database for seamless integration of common information Remote technical support is available PERSONA Campus Online Software runs as a standalone system on a single PC or networked using existing TCP IP networks Items included in your...

Страница 4: ... 3599 Wire Harness LCU to Inteface PCB 11 52 0875 PG Passport 1000 Spacer Included only with 1 3 8 thick doors 12 52 0748 Inside Mounting Plate 13 52 3804 Screw Pack 14 52 3906 Grounding Harness 15 52 0871 Wire Cover Plate 16 52 0751 Battery Cartridge 17 52 4245 Modular Component 18 52 3592 Inside Escutcheon Assembly 2 3 5 8 9 10 12 13 1 4 6 7 5 11 13 16 18 14 17 13 15 10 31 12 A7809B 4 Copyright ...

Страница 5: ...rep 4 68 7255 Chassis Assembly 1 68 7256 Chassis Assembly Fire Rated 68 5836 Chassis Assembly Latch Guarding 68 5837 Chassis Assembly Fire Rated Latch Guarding 5 13 0074 Cylinder Connecting Screw 2 6 68 3922 Screw Pack 1 7 68 0406 Chassis Cover Without Latch Guarding 1 68 1014 Chassis Cover With Latch Guarding 5 A7809B Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Group company All ri...

Страница 6: ...ep 4 99 2401 8900 Lock body Assembly LHR 1 99 2402 8900 Lock body Assembly RHR 99 2403 8900 Lock body Assembly LHR Non Beveled Door 99 2404 8900 Lock body Assembly RHR Non Beveled Door 5 99 2628 Screw Pack 1 6 68 7253 Chassis Assembly LHR 1 68 7254 Chassis Assembly RHR 7 68 2143 Screw Pack 1 8 68 0407 Chassis Cover 1 10 31 12 A7809B 6 Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Grou...

Страница 7: ...ate holes ET through bolt holes ET through bolt hole ET through bolt hole 1 Exit Hardware Door Preparation Prior to installation all holes must be free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available reinforcements should be installed Prepare door according to appropriate template Field template A7951 or wood doors Manufacturer s template ...

Страница 8: ...wire channel cutout for wood doors and access hole for metal doors 2 Mount exit chassis carefully DO NOT PINCH HARNESS WIRES 3 ET spindle will engage into the hub of exit device chassis 4 Secure chassis and ET with 2 1 4 20 x 2 3 8 flat head machine screws A Outside Trim 1 For exterior applications ET gasket 52 0263 should be used to seal between ET escutcheon and outside door surface 2 Route harn...

Страница 9: ...to hub of exit device chassis 3 Make sure ET harness is clear of cylinder and cylinder tailpiece D Securing Cylinder 1 Secure cylinder to exit chassis using 2 12 24 x 1 7 8 connecting screws 2 Fasten exit chassis to door using 4 10 wood screws for wood door or 10 24 machine screws for metal door Inside of door Fig 2C 9 A7809B Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Group company...

Страница 10: ... 2 Drill 2 3 32 diameter by 1 2 deep holes as shown Fig 4A1 3 Ensure stamped side of plate goes against door 5A Installation of Outside Escutcheon with Weatherseal Gasket Optional Back side of wire cover plate Chassis Cover NOTE For non fire rated door applications an optional gasket may be used as a weatherseal between the escutcheon and the outside door surface Peel off adhesive backing and atta...

Страница 11: ...o bottom right screw and note upright positioning of lug as shown Fig 5B2 4 Insert other corner screws and tighten all fastening the outside escutcheon to the door Fig 5B1 IMPORTANT If the following step is skipped the product will not be UL compliant 5 Attach two 2 8 x 3 8 flat head wood screws for wood doors or 2 8 32 x 3 8 flat head machine screws for metal doors Fig 5C Tighten securely Fig 5B2...

Страница 12: ...rd reader connector 14 pin 3 Secure the LCU connector 7 pin NOTE Connectors go on only one way Do not force and do not offset connectors Be sure they are completely seated flush Inside of door From ET Control From Outside Trim LCU Card Reader From Outside Trim Keypad From Outside Trim ground Fig 6B2 Detail Fig 6B1 Detail 6B Installation of Connectors 10 31 12 A7809B 12 Copyright 2012 Sargent Manuf...

Страница 13: ... be placed inside to avoid being pinched 2 Straighten escutcheon and tighten securely 8 Installation of Inside Escutcheon Rim Installation Instructions Continued SARGENT mortise lock with and without deadbolt Switch 1 and 2 OFF Switch 3 ON SARGENT cylinder or exit locks Switch 1 OFF Switch 2 and 3 ON PERSONA PG Controller DIP Switch Settings Fig 7A PERSONA PG controller DIP switch location 7 Batte...

Страница 14: ...Preparation NOTE Instruction examples show wood door installation For metal doors route cables inside door Left Hand Reverse LHR Right Hand Reverse RHR Inside Outside Prior to installation all holes must be free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available reinforcements should be installed Prepare door according to exit installation in...

Страница 15: ...tallation Instructions Continued A Outside Trim 1 Slide mortise lock into door and securely fasten with 2 flat head screws 2 For exterior applications gasket 52 0263 should be used to seal between ET escutcheon and outside door surface 3 Route ET harness through wire cutout and out other side of door 4 Place ET control on door with spindle inserted through mortise lock B Exit Chassis Fig 2B1 Detai...

Страница 16: ... C Cylinder Installation Note For devices without cylinders skip this section 1 Back cylinder set screw out of mortise lock 2 Insert cylinder through ET control and thread into mortise lock until cylinder is flush with ET 3 Tighten cylinder set screw Cylinder set screw 16 A7809B Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproductions in whole or i...

Страница 17: ... holes as shown 3 Stamped side of plate goes against door 4 Secure wire cover plate to door directly above chassis cover note orientation using two 2 6 x 1 2 flat head security torx wood screws Note Position lower edge of cover plate against the chassis cover to ensure no wires are visible 2 3 32 dia by 1 2 deep holes Inside of door Back side of wire cover plate 4 Wire Cover Instructions Wood Door...

Страница 18: ...unting plate over the indicated holes As you feed controller keypad battery and grounding cables through the side opening Fig 5B1 tuck the ferrite bead carefully under the reader Note Insert either of the top corner screws to hold the plate as you feed the cables through Also refer to Step 6B Inside of door Outside Passport trim Attach two 2 8 x 3 8 flat head wood screws for wood doors or 2 8 32 x...

Страница 19: ...ail Fig 6B1 Detail Secure the following connectors onto the circuit board Fig 6B1 and 6B2 1 Secure the mortise lock body assembly connector 10 pin 2 Secure the mortise keypad card reader connector 14 pin 3 Secure the LCU connector 7 pin NOTES Connectors go on only one way Do not force and do not offset connectors Be sure they are completely seated flush 10 31 12 A7809B 19 Copyright 2012 Sargent Ma...

Страница 20: ...inder or exit locks Switch 1 OFF Switch 2 and 3 ON 1 Position inside escutcheon Fig 8A insert screws top and bottom and tighten securely Do not over tighten Note All wires should be placed inside to avoid being pinched 2 Straighten escutcheon and tighten securely Battery pack Fig 8A 2 8 32 x 1 2 pan head security torx machine screws Inside of door 7 Battery Battery Pack Installation and DIP Switch...

Страница 21: ...me Once Bluetooth pairing is complete these steps do not need to be repeated to program locks Section 8 Lockset Programming 1 To begin highlight by tapping the button and select the Settings menu 2 Next tap the Connections tab at the bottom of the screen and highlight the Bluetooth icon from the Settings menu Setting up the Locklink and Contact Card for First Use Pairing the Pocket PC with the Con...

Страница 22: ... is not flashing remove the contact card wait for the lights to go dark then reinsert it before tapping Retry If this step fails repeatedly then contact PERSONA technical support at 800 481 8464 1 Enter 1234 when prompted for Passcode 2 Tap the COM Ports tab at the bottom of the screen Note the COM port number assigned to the Firefly device NOTE If you do not see the FireFly EAE0 device in the COM...

Страница 23: ...then Setup 2 Pick the COM port noted in Step 6 Check the box Use Bluetooth and click Apply 4 Type in your password You can use the onscreen keyboard entry method to enter information Once you have entered your password you will begin on the Upload screen This is the proper place to be for programming locks 5 To access the full screen keyboard shown at right tap on the ellipsis three dots next to t...

Страница 24: ...ystem by interpreting the lock data to control each lock s behavior 1 Highlight by tapping the name of the lock that you wish to program 2 Tap the button to completely initialize the lock the message Alert Make sure the Contact Card is Inserted or has power If the list of locks is longer than the display locate the lock using the scroll bar at the right of the display or use the button at the top ...

Страница 25: ...mission of Sargent Manufacturing Company is prohibited Passport 1000 PG Exit Device 6 Reinsert Contact Card a second time to initialize the program Note You should hear the motor run briefly 7 Program initializes and directs you to remove the Contact Card 8 Follow the on screen directions and reinsert the Contact Card a third time Lockset Programming Instructions Continued ...

Страница 26: ...1000 PG Exit Device Lockset Programming Instructions Continued 9 Remove the Contact Card 10 To exit and return to the program screen tap the button 11 After programming the new lockset verify operation by performing the Operational Check refer to Section 9 12 Repeat this procedure for each lock to be programmed with lock data NOTE With a successful upload the time and date that the lock was progra...

Страница 27: ... without a keypad the following checks apply Insert test card marked NO PIN and retract a Ensure lockset displays a green flash and no other lights b Ensure outside lever retracts latch the door opens and that there is no binding against lock case wire harness or other obstructions For units with a keypad test the keypad by using the following checks Create and insert a test card marked PIN 1234 a...

Страница 28: ...for new construction renovation and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY is the global lead...

Отзывы: