Fig. 2B2
Inside of door
Exit chassis
Grounding harness
(wood doors only)
(2) 1/4” x 2-3/8”
flat head machine
screws (secures ET)
ET control
Fig. 2A
Wire harness
(from motor)
Mortise
lock body
1. Route “ET” harness along track cutout for wood doors and access hole for metal doors.
2. Mount exit chassis carefully.
Do not pinch harness wires.
3. Position exit chassis on door with lever arm under rear section of mortise lock.
4. Using (2) 1/4-20 x 2-3/8” flat head screws, attach chassis to “ET” control.
(2) #12 x 1”
wood screws
or
(2) #12-24 x
1/2” machine
screws
Latchbolt
Lever arm
Lever
Chassis
Mortise Installation Instructions (Continued)
A. Outside Trim
1. Slide mortise lock into door
and securely fasten with (2)
flat head screws.
2. For exterior applications, gasket
(52-0263) should be used to
seal between “ET” escutcheon
and outside door surface.
3. Route “ET” harness through
wire cutout and out other
side of door.
4. Place “ET” control on door
with spindle inserted through
mortise lock.
B. Exit Chassis:
Fig. 2B1
Detail
Outside of
door
ET wire harness
(from motor)
ET Gasket
2 – Installation of Outside Exit Trim (ET),
Exit Chassis and Cylinder
15
A7809B
Copyright © 2012, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/31/12
Passport 1000 PG Exit Device