13. To install the battery, pull the keypad tab 
out slightly and turn the keypad ring 
counterclockwise. The ring will pull out from the 
base far enough to reveal the battery 
connector. Attach the battery and place it in the 

battery compartment. 

14. Push the keypad ring back against the base 
and turn it clockwise until it clicks into place. 
Test the lock function at least three times with 
the door open before closing the safe. 

2007 D•Drive Specifications  

 

Attaching Screws:

 Use only the screws provided with the lock. They must engage the mounting plate by at least four full threads. Do not use lock washers or thread 

sealing compounds. 

Recommended Attaching Screw Torque:

 30 to 40 inch-pounds (33,9 to 45,2 Nm) for the lock body. No more than 15 inch-pounds (1,695 Nm) for the keypad 

base attaching screws. 

Minimum Lock Cable (Spindle) Hole Diameter:

 0.375 inch (9,5 mm)  

Maximum Lock Cable (Spindle)  Hole Diameter:

 0.406 inch (10,3 mm) 

Lock is Designed to Move:

 2.5 lbs. (11,12 Newtons) continuous / 10 lbs. (44,48 Newtons) maximum 

Lock Bolt Maximum Free Movement:

 0.352 inch (8,95 mm) 0.109 inch (2,77 mm) remains outside the edge of the lock case when bolt is fully retracted. 

Maximum Bolt End Pressure:

 lock is designed to withstand at least 225 lbs. (1000 Newtons) 

Maximum Bolt Side Pressure:

 safe and container boltwork or locking cam designs must never apply more than 225 lbs. (1000 Newtons) of side pressure on the 

lock bolt. 

Mounting Environment:

 The lock body is designed to be mounted inside a secure container. The container must be constructed to offer protection against physical 

attack directed at the lock. The amount of protection is dependent on the desired level of security for the system as a whole. Lock protection may include barrier materials, 
relock devices, thermal barriers, thermal relock components, or any combination of these. Relock device attaching screws must NOT be longer than the depth of the 
tapped hole provided in the lock case. 
A minimum distance of .150 inch (3,8 mm) is recommended between the end of the lock case and the closest approach of the safe’s blocking bar or cam plate (which is 
normally blocked by the extended lock bolt). Maintaining this clearance will allow the lock to deliver optimum performance. 

Code Restrictions:

 Personal data that can be related to a code holder, such as a birth date, street number, or phone number, should not be used in creating a lock 

code. Avoid codes that can be easily guessed 

Note:

 Every installation of this product must comply with these requirements and those in the product installation instructions to qualify for the manufacturer’s warranty 

and to comply with EN1300 requirements. 

ALL DIMENSIONS IN INCHES 