Installation Instructions for Model 2007 D•Drive Safe Lock 

The Model 2007 is a non-handed electronic safe lock. It will be necessary to plug the provided cable into the lock. This is a phone-type connector that will only insert one 
way (Figure A). Make sure it is fully inserted and locked into the lock case receptacle. The lock cable must to be routed in the recessed channel in the lock’s cover. Figure B 

shows the proper cable placement The cable runs through the opening of the case and on through the safe’s spindle hole to the keypad. 

Figure A 

Figure B 

1. Measure the safe’s door thickness (distance 
from the mounting surface for the lock to the 
mounting surface for the keypad. Add 

¾

” (19 

mm), and cut the aluminum spindle to this 
length. 

2. Insert the lock cable into the spindle slot as 
shown. Then slide the cable through the length 
of the slot. 

3. As you slide the last bit of cable through the 
spindle slot, place the spindle into the lock 
body cam. The spindle and cam are configured 
to mate together. 

 

4. Place the end of the lock cable through the 
safe door from inside. Pulling gently on the 
cable insert the lock with attached spindle 
through the safe door so that it can be attached 
to the door’s mounting plate with the three 
screws provided. 
 
5. Place the lock cable through the center of 

the keypad base as shown. 

6. Pulling gently on the cable, move the keypad 
base against the safe door, and attach it using 
the two machine screws provided. Do not 

tighten beyond 15 inch-pounds (1,695 Nm). 

7. If not already attached, plug the battery 
connector cable into the white receptacle on 
the back of the keypad. 

8. Plug the lock cable into the black receptacle 
on the back of the keypad. Note that there are 
two raised ridges on the cable plug and two 
matching slots in the keypad receptacle. Align 
these features before inserting the plug into the 
receptacle. 
 

9. Place the lock cable into the recessed area 

of the keypad provided for it on the left side. 

10. Place the battery cable through the slot at 
the base of the battery cable compartment and 
place the remainder of the cable in the 

compartment. 

11. Keeping the lock cable and the battery 
cable in their respective compartments, place 
the keypad onto the base. The top seats into 

the base first, then the bottom. 

12. Install and tighten the keypad holding screw 
as shown. Use the one-way security screw for 
EN1300 applications. The Phillips screw is 
acceptable for all other applications. Once the 
screw is in place, cover it with the self-stick 
S&G logo after peeling the protective film off of 
the logo. 