3.6 — Command 46: Setting Up the Time Delay Override Options
When the time delay feature is enabled, the A-Series lock can be programmed with a time delay override (TDO) feature that will allow
a specific user to bypass the time delay countdown. The time delay override code must always be setup in PIN position 29.
There are two types of TDO available. TDO TYPE 1 requires that the time delay override code is entered within the first minute of the
time delay countdown. In other words, a User must start the time delay countdown by entering their code. If the time delay override
code is entered within the first minute, then the lock will open.
Delay override feature must be made during the opening window. If a time delay value has already been entered, then any changes
notes below:
TDO TYPE 2 will allow the lock to be opened by the time delay override code without requiring another User start the time delay
countdown.
Set time delay override
If the time delay has already been set, enter a User Code to start the time delay. When the time delay expires (the lock emits 10 rapid
beeps) and the opening window has begun, immediately proceed to change the time delay override by performing the following steps:
The TDO TYPE 2 function has now been enabled. The code in position 29 can now be used to open the lock without waiting for the time
delay countdown.
3.7 — Command 47: Setting Up the Time Delay
The 6128/6129/6106 can be programmed with a time delay feature. Time delay applies to Bank Users only. The time delay can be set
from 0 to 99 minutes. The LED red light on the keypad flashes and a single beep sounds every 10 seconds as a reminder that the lock
is in the time delay period.
To open the lock, a User must enter their User Code to start the time delay period, wait the length of the time delay period and then
enter a valid User Code during the opening window.
If the lock is not opened during the open window, it resets, and the process must be restarted.
The 6128/6129/6106 comes from the factory with no time delay set.
Process
Set TDO 0/1/2
1) Enter: 46*
1) Enter: 46*
2) Enter: Programmer Code + #
♪♪♪♪♪
2) Enter: 00123456 #
♪♪♪♪♪
3) Enter: Time Delay Override Type (0/1 2)) + #
♪♪♪
3) Enter: 0/1/2 #
♪♪♪
4) Enter: Time Delay Override Type (0/1/ 2)) + #
♪♪♪
4) Enter: 0/1/2 #
♪♪♪
NOTE:
If a time delay value has already been entered, then any changes to the time delay
override feature must be made during the opening window.
NOTES:
1)
If the time delay has already been set, changes to the opening window and time
delay duration can only be made during the opening window.
2)
IMPORTANT: Do not set the time delay until you have finished all other
programming functions, or you will have to wait through the time delay before
making any other programming If changes.