STR 2000 Series Transceiver Programming Manual
Sapling, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 Phone: (215) 322-6063
Fax: (215) 322-8498 www.Sapling-Inc.com
Press the “Set Hour” button to enter option 60. A “60”
will appear on the left side of the LED display.
This
option allows the user to enter diagnostic mode.
Press the “Set Minute” button scroll between “E - D”.
Setting the option to “E” will enable the option and will
enter diagnostic mode. Setting the option to “D” will
disable the option, then pressing the “Set Hour” button
will bring the display back to the set time.
Page 9
Press the “Set Hour” button to enter option 43. A “43”
will appear on the left side of the LED display.
This
option allows the user to send the diagnostic to the
slave clocks.
Pressing the “Set Minute” button will
scroll from “01-05”.
01 - Protocol Verification
02 - Comprehensive Test
03 - Manufacturer’s Default
04 - Combination of 02 & 03 (button must be pressed on SAM)
05 - Combination of 02 & 03 (no need to press button on SAM)
09 - Overrides the Previous Diagnostic and Goes Back to the Time
Pressing the “Set Hour” button will advance to option 62.
A “62” will appear on the left of the LED display.
This
option allows the user to set how long (in minutes)
that the information display from the diagnostic will
stay on the clock.
Pressing the “Set Minute” button will
scroll from “00-99”. Pressing the “Set Hour” button will
go back to the displayed time.