Page 7 of 7
7
Return Panel Installation – You will need a light mark outside
of the centerline, to determine where the outer edge of
the Glass Return Panel [I] is. The mark should fall on the miter
cut in the threshold. For a PL60, that mark should be 1-3/16”.
For a PL70 the mark should be 7/8”. For a PL80 the mark
should be 1-1/8”. Orient the Glass Return Panel so that the
return mount hole is toward the front of the enclosure. Slide the
vertical edge of the glass into the SC-658 wall jamb. Line up
the outside, vertical edge with the mark you just made and set
the bottom edge of the glass into the Glass Clips.
8
Install the return mount through the hole in the return glass
panel. A PL60 return mount is shown, for reference.
Things to Remember
– There are two things to take into account during the installation of the “front” of the
shower door.
• There will only be one wall mount bracket used. The other support for the header bar being the return
mount (step 8).
• The threshold for the front of the shower door will be longer than described in the standard installation
instructions, and will need to be miter cut to match the return threshold. To determine the length of the
front threshold, measure the width from the wall, to the pointed tip of the return threshold. Cut the front
threshold to that length, and proceed as described in the standard installation instructions.