background image

INSTALLATION MANUAL

Color CCD Camera

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED 
SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL 
CODES.

Please read this manual before installing and using this unit, and always follow the instructions 
in it for proper use. Please also read the separate INSTRUCTION MANUAL before using the unit 
for proper use.

This unit can be installed on the ceiling or wall. 
When installing, first remove the built-in camera 
from the unit.

b

When routing the cables on ceiling or wall 
surfaces:

Loosen the conduit hole cover fixing screw 

(A)

 

on the back of the camera unit base with the 
hexagonal wrench (small), open the cover 

(B)

and pass the connection cables through the 
conduit hole.

Since the conduit hole cover is not 
waterproof-finished, always be sure to 
seal the cover entirely by puttying, for 
example, upon completion of installation.

Ceiling Installed (see page 1)

Wall Installed (see page 3)

(In-ceiling routing)

(Surface routing)

(In-wall routing)

(Surface routing)

Important

• Be careful when opening holes for installing 

the unit. Work with the power and video 
cables pulled out for easy installation.

• Make sure to properly perform waterproofing 

for the ceiling or wall where you are installing 
the unit.

• Make sure that the surface in the installation 

location has no unevenness and is strong 
enough to bear the total weight of the unit.

• Install this unit in an environment where the 

temperature range stays between -10°C 
and +50°C (no condensation allowed).

• As a precaution against static electricity 

damage, touch a nearby metal object (door 
knob, etc.) to dissipate static electricity in 
your body before touching this unit.

A

B

VDC-DP7585P

E

ngl

is

h

F

ran

çai

s

Deutsc

h

中文

简体

L5BH2_XE(INSTALLATION).book  0 ページ  2006年6月30日 金曜日 午後6時34分

Содержание VDC-DP7585P

Страница 1: ...waterproof finished always be sure to seal the cover entirely by puttying for example upon completion of installation Ceiling Installed see page 1 Wall Installed see page 3 In ceiling routing Surface routing In wall routing Surface routing Important Be careful when opening holes for installing the unit Work with the power and video cables pulled out for easy installation Make sure to properly perf...

Страница 2: ...ra unit base F open a cable hole in the cushioning sheet and pass the cables through the cable hole 2Position the arrow 2 on the inner side of the camera unit base F in the direction of the lens The arrow is located roughly in the center of the panning range 3Set the camera unit base F on the ceiling and secure it by tightening suitable screws and washers G through the screw holes 4 places Length ...

Страница 3: ...by moving the lens unit manually Make the arrow AA beside the lens point upwards the video image will be upside down if pointing downwards 2Shape the flat cable on the back of the lens unit 1 Hook the cable on the back of the clamp as shown in the figure 2 Pull the cable in the arrowed direction until the sag is gone 3 Fold over the excess cable until there is no more sag and insert it into the ho...

Страница 4: ...he hexagonal wrench large 5 Install the dome cover N P L R R M Installing on the Wall See Installing on the Ceiling see page 1 1Attach the cushioning sheet A to the back of the camera unit base B open a cable hole in the cushioning sheet and pass the cables through the cable hole 2Set the camera unit base B on the wall so that its tightening screws C are perfectly horizontal then tighten them secu...

Страница 5: ...mera remotely see page 7 b Check the settings screen or camera angle on a portable monitor see page 7 If the image is upside down correct the orientation by turning down the lens unit rotating it 180 degrees and then turning it up in the arrowed directions See Adjusting the lens position and shaping the flat cable on page 2 See Installing on the Ceiling see page 3 3 Mount the camera unit D E E F 4...

Страница 6: ...U coaxial cables can be used when distance between devices is short but not in duct or aerial routing Cable type Length RG 59U 3C 2V 150 m max RG 6U 5C 2V 300 m max RG 11U 7C 2V 350 m max b With DC 12 V Check that polarity is correct RED BLACK WHITE For the connections use cables thicker than 18 AWG RED BLACK To prevent electromagnetic interference On the cable for power supply Be sure to attach t...

Страница 7: ...d to be color or black and white using an external switch For details see Adjusting DAY NIGHT Function in the INSTRUCTION MANUAL Color or Black and White Setting GRAY PURPLE Alarm input signal Alarm Signal Input GRAY BLUE Open Color Closed Black and White GRAY YELLOW Make sure that COLOR is selected All connection cables should be 24 AWG or higher with a maximum length of no more than 600 m ORANGE...

Страница 8: ...on the circuit board to a monitor using an alligator clip cable Do not forget to remove the cable after you have finished checking A dedicated MONITOR OUT connector is provided for portable monitors b To check the settings screen and make changes 1 Hold down the SET button 1 for over a second The main menu appears 2 Select a menu by pressing the Select button 2 up and down 3 Select the setting ite...

Отзывы: