Settings/
Adjustments
Specifying Alarm Output
For accessing the MAIN MENU, see page 13 – 14.
If you have connected an external beeper or indicator to the ALARM OUT (alarm output) terminal on the rear
panel, specify the following settings. You can also obtain a notification on the screen while an alarm occurs.
(For connecting alarm devices, see page 10.)
1
1
1
1
Select “POLARITY” and specify a polarity for the
signal.
NO : Normal Open (Closes when alarm input is detected).
NC : Normal Close (Opens when alarm input is detected).
2
2
2
2
Select “ALARM TIME” and specify duration time
to output alarm.
• Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M
(S = second, M = minute)
3
3
3
3
Set “MENU” to “END” and press the SET button.
R
Finishes the settings screen and returns to the normal
monitoring screen.
• If you want to return to the previous screen, select “BACK” and
press the SET button.
ALARM OUT SETTING (Alarm output)
ALARM
OUT
ON
SET
ALARM
(SET)
SET
MAIN MENU
LANGUAGE
SET
TITLE
OFF
SYNC
INT
EXPOSURE
SET
DAY/NIGHT
AUTO
WHITE BALANCE
ATW
OPTION
SET
PRESET
OFF
MENU
END
ALARM
SET
ALARM SETTING
ALARM SIGN
OFF
PRESET
OFF
MENU
BACK
ALARM IN
SET
ALARM OUT
ON
MEMO: For the electrical characteristics of alarm output, the
nominal output of the open collector (grounded emitter) is
18 V 25 mA.
ALARM OUT SETTING
ALARM TIME
5S
POLARITY
NO
MEMO: You can display alarm on the monitor screen.
(See page 45)
! #$! %&'()*+