OUTPUT TERMINALS
SERIES OUT/NON REC OUT terminal
setting
The output at the SERIES OUT/NON REC OUT terminal
can be set.
1
Press the MENU button until the (SET UP 5) menu is
displayed.
NOTE:
•
If “OUTPUT” is set to “NON REC”, the “NON REC
OUT” line will be displayed under the “OUTPUT”
line.
@@@@@@@<SET@UP@5>
*INPUT@OUTPUT@ALARM
*OUTPUT@@@@@@@SERIES
*NON@REC@OUT@@ACTIVE@LOW
*WARN.@OUT@@@@TRANSPORT
*REMOTE@@@@@@@EJECT
*TAPE@@@@@@@@@T-160
2
Press the
]
button, until the “OUTPUT” setting is
flashing.
3
Press the
l
(or
j
) button, to select the desired
output mode.
SERIES . . . . . The SERIES OUT/NON REC
OUT terminal will be set to
SERIES OUT.
If during series recording, the
counter reading reaches 7:57:00
or the tape reaches the end, a
LOW signal (0 V) is output. The
LOW (0 V) signal is output for
about 70 seconds after the end of
the tape is reached.
NON REC . . . The SERIES OUT/NON REC
OUT terminal will be set to NON
REC OUT.
If “OUTPUT” is set to “NON REC”, please continue with
step
4
.
4
Press the
]
button.
5
Press the
l
(or
j
) button to select the desired output.
ACTIVE LOW
. . Normally DC 5V are output
between the SERIES OUT/NON
REC OUT and the COM
terminals. If during recording the
VCR enters a mode other than
recording (i.e. recording pause,
stop mode, etc.), the output
become 0 V (Low). If recording is
resumed, then the output become
5 V (High).
ACTIVE HIGH
. . Normally 0V are output between
the SERIES OUT/NON REC OUT
and the COM terminals. If during
recording the VCR enters a mode
other than recording (i.e.
recording pause, stop mode, etc.),
the output become 5 V (High). If
recording is resumed, then the
output become 0 V (Low).
NOTES:
•
If “NON REC OUT” is set to “ACTIVE HIGH”, a
throwaway pulse will be output from the SERIES
OUT/NON REC OUT terminal when power is
restored after an outage, when the power is turned
on or when the ALL RESET button is pressed. This
will continue until the microprocessor starts
operating. If this output terminal is connected to
some other device, the device should be set or
adjusted so that it is not affected by the throwaway
pulse. If set to “ACTIVE LOW”, this kind of pulse is
not output, and so it is recommended that you use
the “ACTIVE LOW” setting.
•
If in the (SET UP 2) menu, in the “BUZZER”
section, “WARNING” is set to “Y”, a buzzer will be
heard while the VCR is in non recording mode. The
buzzer will stop if the STOP button is pressed (the
output signal will remain).
6
Press the PAUSE/SEARCH button to save the setting.
ALARM IN/CLOCK IN and ALARM
OUT/CLOCK OUT terminal setting
1
Press the MENU button until the (SET UP 5) menu is
displayed.
°
The “INPUT OUTPUT” setting is flashing.
2
Press the
l
(or
j
) button to select desired
input/output mode.
ALARM. . . . . . The ALARM IN/CLOCK IN
terminal is set to ALARM IN and
the ALARM OUT/CLOCK OUT
terminal is set to ALARM OUT.
CLOCK SET. . The ALARM IN/CLOCK IN
terminal is set to CLOCK IN and
the ALARM OUT/CLOCK OUT
terminal is set to CLOCK OUT.
3
Press the PAUSE/SEARCH button to save the setting.