− 60 −
1-2 Restrictions on installation
(1) Installation restrictions for heat pump unit
(View as seen from above)
(View as seen from side)
*All the dimensions shown are
required to maintain the unit’s
performance.
(2) Restrictions on pipes between heat pump unit and tank unit
(View as seen from side)
Overall pipe length:
Within 15 m
Number of bends:
Not more than 6
Vertical interval:
Within 3 m
Tube-shaped pipe:
Within 3 m
Tank unit
Heat pump unit
Within
3 m
100 mm
or more
300 mm or more
100 mm
or more
Heat pump unit
Front panel
300 mm or more
100 mm
or more
Heat pump unit
Front panel
Front panel
300 mm
or more
100 mm
or more
Stand