6
2-2-2. Outdoor Unit
Outdoor Unit
SAP – CV94GJ
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Compressor
Type
DC Rotary (Hermetic)
Compressor model
C-1RV63H0W 80662180
Compressor oil … Amount
cc
320
Coil resistance (Ambient temp. 25°C)
Ω
R – S: 0.641
S – T: 0.641
T – R: 0.641
Safety devices
CT (Peak current cut-off control)
YES
Compressor discharge temp. control
YES
Operation cut-off control in abnormal ambient temp.
—
Run capacitor
µF
—
VAC
—
Crankcase heater
—
Fan & Fan Motor
Type
Propeller
Q’ty … Dia.
mm
1 … 370
Fan motor model … Q’ty
UE6S-21AB5PB-C … 1
No. of poles … rpm (220V, High)
6 … 820
Nominal output
W
20
Coil resistance (Ambient temp. 20°C)
Ω
WHT – BRN: 242.4
WHT – YEL: 156.1
YEL – PNK: 252.0
Safety devices
Type
Thermal protector
Operating temp.
Open
°C
130 ± 8
Close
°C
79 ± 15
Run capacitor on control PCB (A)
µF
1.5
VAC
440
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
1
Fin pitch
mm
1.2
Face area
m
2
0.352
External Finish
Acrylic baked-on enamel finish
Control PCB (A) / Control PCB (B)
Part No.
CB-CV94GJ / POW-CV94GJH-B
Controls
Microprocessor
Control circuit fuse
250V, 3.15A / 250V, 20A