17
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor unit
SAP-KV94GJ
Outdoor unit
SAP-CV94GJ
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.33
Power input
kW
0.026
0.28
0.062
Rating conditions:
Indoor air temperature: 27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature: 35
°
C D.B.
Cooling
3.09
0.712
3.70
0.80
Indoor unit
SAP-KV124GJ
Outdoor unit
SAP-CV124GJ
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.33
Power input
kW
0.026
0.28
0.062
Rating conditions:
Indoor air temperature: 27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature: 35
°
C D.B.
Cooling
4.59
1.052
5.20
1.14