To unmount indoor unit
Press the 2
L
L
marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 42)
3-9. Drain Hose
a)
The drain hose should be slanted downward to
the outdoors. (Fig. 43)
b)
Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the
hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 44)
* Foamed polyethylene or its equivalent is recom-
mended.