17
Indoor Unit
SAP – K122AH
Outdoor Unit
SAP – C122AH
240V Single Phase 50Hz
RATING CAPACITY
3.20 kW
AIR FLOW RATE
470 m
3
/h
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
30
35
40
43
TC
2.94
2.80
2.63
2.42
CM
1.10
1.18
1.26
1.35
21
SHC
1.96
1.89
1.80
1.69
15
23
SHC
2.18
2.11
2.02
1.92
25
SHC
2.41
2.34
2.25
2.14
27
SHC
2.64
2.56
2.47
2.37
29
SHC
2.86
2.79
2.63
2.42
31
SHC
2.94
2.80
2.63
2.42
TC
3.16
3.01
2.83
2.60
CM
1.13
1.21
1.29
1.38
21
SHC
1.73
1.65
1.57
1.46
17
23
SHC
1.95
1.88
1.79
1.68
25
SHC
2.18
2.11
2.02
1.91
27
SHC
2.41
2.33
2.24
2.14
29
SHC
2.63
2.56
2.47
2.36
31
SHC
2.86
2.78
2.69
2.59
TC
3.36
# 3.20
3.01
2.77
CM
1.17
1.25
1.33
1.42
21
SHC
1.49
1.41
1.32
1.22
19
23
SHC
1.71
1.64
1.55
1.44
25
SHC
1.94
1.86
1.77
1.67
27
SHC
2.16
2.09
2.00
1.89
29
SHC
2.39
2.31
2.22
2.12
31
SHC
2.61
2.54
2.45
2.34
TC
3.56
3.39
3.19
2.93
CM
1.20
1.29
1.37
1.46
23
SHC
1.46
1.39
1.30
1.20
21
25
SHC
1.69
1.61
1.53
1.42
27
SHC
1.91
1.84
1.75
1.65
29
SHC
2.14
2.06
1.98
1.87
31
SHC
2.36
2.29
2.20
2.10
TC
3.77
3.56
3.33
3.10
CM
1.23
1.32
1.41
1.50
23
25
SHC
1.42
1.34
1.25
1.16
27
SHC
1.65
1.56
1.47
1.39
29
SHC
1.87
1.79
1.70
1.61
31
SHC
2.10
2.01
1.92
1.84
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
Содержание SAP - C122AH
Страница 13: ......
Страница 52: ...SANYO Electric Co Ltd Osaka Japan SM700566 Sep 2003 50 Printed in Japan ...