21
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.25
5.67
6.1
Power Input
kW
0.040
0.060
1.250
1.35
Full Load Conditions Running Amps.
A
0.18
0.25
6.77
7.2
Power Input
kW
0.040
0.060
1.500
1.60
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.25
5.57
6.0
Power Input
kW
0.040
0.060
1.220
1.32
Full Load Conditions Running Amps.
A
0.18
0.25
6.67
7.1
Power Input
kW
0.040
0.060
1.450
1.55
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
Indoor Unit
SAP – K121AHA
Outdoor Unit
SAP – C121AHA