- 83 -
●
description of Motor driving circuit
Lamp Iris Motor
The lamp iris unit is located in the front of lamp. It is controlled by
the IRIS_PWR_ON signal, which is varied based upon the average
luminance level of the input image signal, from pin 143 of IC301.
When the image becomes darker, the lamp iris will be closed, and
when the image becomes brighter, it will be opened.
●
Lamp iris unit
DOOR SW_2 BOARD
DOOR SW_1 BOARD
MOTOR
OPEN
CLOSE
●
door motor
cLoSe
(at dark image)
ceNter
oPeN
(at bright image)
WINDOW EXTENSION
Auto mode
APL of input signal
(OPEN)
(CLOSE)
WINDOW EXTENSION
Open mode
Close mode
APL of input signal
(OPEN)
(CLOSE)
Chassis Block Diagrams
IrIS FIN
(variable)
Motor
door Motor
The projector provides 2 door switches. The door switch-1 (SW8801
on DOOR SW_1 board) turns ON, when the slide shutter is opened.
The door switch-2 (SW8811 on DOOR SW_2 board) turns ON, when
the slide shutter is closed.
If the slide shutter is half-open or close, the lamp does not light.
When turning the projector on, the lamp starts light after SW8801
turning on.
If the slide shutter error occurs during opertion, the POWER
indicator will blinks red and the projector will go to stand-by mode
after cooling.
Содержание PLV-Z4000
Страница 117: ...ME4 Z400000 117 117 M01 M05 M07 M12 M14 M15 M16 M17 M18 M24 M24 M27 M25 Cabinet Front ass y Mechanical Parts List ...
Страница 118: ... 118 ME4 Z400000 118 M22 M26 M31 M32 M34 M46 Optical Parts Location Optical Unit Mechanical Parts List L02 L04 M49 M48 ...
Страница 124: ... ME4AE May 2010 DC 200 Printed in Japan SANYO Electric Co Ltd ...