- 67 -
No.
Adjustment Item
Initial Value
range
Input source / description
109
Cooling Time
3
0 - 15
0 : always On, 1 : 30sec, 2 : 60sec, 3 : 90sec, - - 15 : 450sec
110
Temp Error Cooling Time
3
1 - 15
1 : 30sec, 2 : 60sec, 3 : 90 sec - - - 15 : 450sec
111
Average Time
1
0 - 10
0 : 10sec, 1: 30sec, 3 : 90sec, - - - - 10 : 300sec
112
Change Normal
0
0 - 1
Lamp Watage Max 0 : Normal1 : Forced lamp Max
113
Dac Change Speed
2
1 - 10
DAC change time (sec)
114
Fan1 Initial Vol
55
0 - 255
FAN1 Initial voltage
115
Fan2 Initial Vol
40
0 - 255
FAN2 Initial voltage
116
Fan3 Initial Vol
60
0 - 255
FAN3 Initial voltage
117
Fan4 Initial Vol
40
0 - 255
FAN4 Initial voltage
118
Fan5 Initial Duty
113
1 - 510
FAN5 Initial DUTY ratio
119
Fan Keep Time
15
0 - 180
FAN Initial voltage keep time (sec)
120
Fan Min Keep Time
60
0 - 180
FAM minimum voltege keep time (sec)
121
Shutdown Temp A
15
0 - 100
Temprature setting Sensor A at the shutdown (°C)
122
Shutdown Temp B
20
0 - 100
Temprature setting Sensor B at the shutdown (°C)
123
Shutdown Temp C
20
0 - 100
Temprature setting Sensor C at the shutdown (°C)
124
Shutdown Temp B-A
20
0 - 100
Temprature setting Sensor <B-A> at the shutdown (°C)
125
Shutdown Temp C-A
20
0 - 100
Temprature setting Sensor <C-A> at the shutdown (°C)
126
Shutdown Time A
20
0 - 30
Temprature setting Sensor A at the shutdown (min)
127
Shutdown Time B
10
0 - 30
Temprature setting Sensor B at the shutdown (min)
128
Shutdown Time C
10
0 - 30
Temprature setting Sensor C at the shutdown (min)
129
Shutdown Time B-A
20
0 - 30
Temprature setting Sensor <B-A> at the shutdown (min)
130
Shutdown Time C-A
20
0 - 30
Temprature setting Sensor <C-A> at the shutdown (min)
131
Control Curve Change Time
1
0 - 10
132
Lamp Monitor SW
0
0 - 1
0 : Off 1 : On
133
Lamp Voltage
- - -
30 - 90
Read only
134
Lamp Vol Threshold
60
50 - 90
135
Fan Speed Gain
300
0 - 1500
136
Lamp Keep Time
90
0 - 255
137
Temp Test Mode
0
0 - 12
138
Fan Cooling Vol Up
0
0 - 145
139
Fan Min. Keep Time
0
0 - 15
140
CF dif. Normal Fan2 Min. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Normal/Temp. Min)
141
CF dif. Normal Fan4 Min. Down
285
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Min)
142
CF dif. Normal Fan5 Min. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Min)
143
CF dif. Normal Fan2 Max. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Normal/Temp. Max)
144
CF dif. Normal Fan4 Max. Down
285
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Max)
145
CF dif. Normal Fan5 Max. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Max)
146
CF dif. Eco Fan2 Min. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
147
CF dif. Eco Fan4 Min. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
148
CF dif. Eco Fan5 Min. Down
450
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
149
CF dif. Eco Fan2 Max. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Eco/Temp. Max)
150
CF dif. Eco Fan4 Max. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Eco/Temp. Max)
151
CF dif. Eco Fan5 Max. Down
450
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Eco/Temp. Max)
152
CF dif. Auto Watt Max. Fan2 Min. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Auto_Max/Temp. Min)
153
CF dif. Auto Watt Max. Fan4 Min. Down
285
0 - 3150
DOWN : at Cinema filter modo Fan revolution Auto_Max/Temp. Min)
154
CF dif. Auto Watt Max. Fan5 Min. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Min)
155
CF dif. Auto Watt Max. Fan2 Max. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Auto_Max/Temp. Max)
156
CF dif. Auto Watt Max. Fan4 Max. Down
285
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Max)
157
CF dif. Auto Watt Max. Fan5 Max. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Miax
158
CF dif. Auto Watt Min. Fan2 Min. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Auto_Min/Temp. Min)
159
CF dif. Auto Watt Min. Fan4 Min. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution Auto_Min/Temp. Min)
160
CF dif. Auto Watt Min. Fan5 Min. Down
450
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Min)
161
CF dif. Auto Watt Min. Fan2 Max. Up
0
0 - 3150
UP : at Cinema filter modo Fan revolution (Auto_Min/Temp. Max)
162
CF dif. Auto Watt Min. Fan4 Max. Down
315
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Max)
163
CF dif. Auto Watt Min. Fan5 Max. Down
450
0 - 3150
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Miax
164
Auto2 FAN4 Speed Offset
405
0 - 3150
FAN4 UP revolution (At Lamp mode Auto2)
Electrical Adjustments
Содержание PLV-Z4000
Страница 117: ...ME4 Z400000 117 117 M01 M05 M07 M12 M14 M15 M16 M17 M18 M24 M24 M27 M25 Cabinet Front ass y Mechanical Parts List ...
Страница 118: ... 118 ME4 Z400000 118 M22 M26 M31 M32 M34 M46 Optical Parts Location Optical Unit Mechanical Parts List L02 L04 M49 M48 ...
Страница 124: ... ME4AE May 2010 DC 200 Printed in Japan SANYO Electric Co Ltd ...