-26-
■
Adjustment
Caution :
Other adjustment items are not related to service and a maintenance. Don't press the POINT (L) and (R) button
at the time of those adjustment items. Otherwise it may cause loss of product safety.
■
ELECTRICAL ADJUSTMENTS
2. Signal Center Adjustment
Equipment
Digital voltmeter.
Input mode
Input 2 [RGB Analog]
Input Signal
16 step gray scale signal
Enter the Service mode.
Adjust below values of each test points by the POINT L or
R button.
Item no.
Test Point
Adjustment value
1
TPV1R
6.5 ± 0.05 V-DC.
2
TPV1G
6.5 ± 0.05 V-DC.
3
TPV1B
6.5 ± 0.05 V-DC.
[Adjustment Condition]
●
Input signal
Video signal .......................... 1.0Vp-p/75
Ω
terminated, 16 steps gray
scale, white 100% and white 50% pat-
tern (Composite video signal)
Computer signal .................... 0.7Vp-p/75
Ω
terminated, 16 steps gray
scale pattern (SVGA)
Component Video signal........ 0.7Vp-p/75
Ω
terminated, 16 steps gray
scale, white 100% and black 0% pattern
(480i format and 480p format)
●
Picture control mode ................ “STANDARD” mode unless otherwise
noted.
Note:
Please refer to “Service Adjustment Menu Operation” for entering to the service mode and adjusting the ser-
vice data.
White 100%
Black 100%
16 steps gray scale pattern
1. Fan Minimum Voltage Adjustment
Equipment
Digital voltmeter
Adjustment Value
3.5 ± 0.05 V-DC
Enter the Service mode.
Adjust values of below items by the POINT L or R button.
Item no.
Fan Location
Test Point
100
FN901
TPFAN1
101
FN902
TPFAN2
102
FN903
TPFAN3
103
FN904/5
TPFAN4
3. Reference Adjustment
Equipment
Oscilloscope
Input mode
Input 2 [RGB Analog]
Input Signal
16 step gray scale signal
Enter the Service mode.
Adjust the amplitude of part A to be below value for each
test point by the POINT L or R button.
Item no.
Test Point
Adjustment value
10
TP35R
10.0 ± 0.1 Vp-p
11
TP35G
10.0 ± 0.1 Vp-p
12
TP35B
10.0 ± 0.1 Vp-p
A
4. Pedestal Adjustment (PC & Component)
Equipment
Oscilloscope
Input Signal
16 step gray scale signal
4-1
Input mode
Input 2 [RGB Analog]
4-2
Input mode
Input 2 [Component: 480p]
Enter the Service mode.
Adjust the level of Black and pedestal to be same for each
test point by the POINT L or R button
in each mode
.
Item no.
Test Point
203
TP35R
204
TP35G
205
TP35B
Pedestal Level = Black Level
Содержание PLV-Z2
Страница 39: ... 39 IC Block Diagrams BA7078AF Sync Separation IC5321 BA9743AFV IC371 ...
Страница 40: ... 40 L3E07070K0A Color Shading Correction IC401 TA1370FG Sync Separation IC5341 IC Block Diagrams ...
Страница 42: ... 42 AN5870SB PC AV SW IC5201 IC Block Diagrams ...
Страница 60: ...Mechanical Optical Parts List Accessories 60 67 61 63 64 65 66 68 69 70 72 73 73 74 75 77 76 78 79 80 ...
Страница 64: ......
Страница 80: ...Diagrams Drawings M4K Z200 ...