-25-
■
Electrical Adjustment
Normal Mode
Service Mode
"MENU"
"INPUT"
"POWER
ON/OFF"
Adjustment item
Adjustment deta value
Service Mode
"Point Up / Down"
137
10
Computer
"Point Left / Right"
Service Mode
137
10
Computer
■
SERVICE ADJUSTMENT MENU OPERATION
■
To enter service mode
To enter service mode press the "MENU" and "INPUT"
buttons on the projector simultaneously and hold for 2
seconds. As shown in a figure, a service mode display
appears on a screen.
■
Adjustment
Adjust service data using the following control buttons.
1. "POINT UP" -------
An item number increases.
2. "POINT DOWN" --
An item number decreases.
3. "POINT RIGHT" --
An adjustment value increases.
4. "POINT LEFT" ----
An adjustment value decreases.
■
To exit service mode
Press the "POWER on/off" button only once on the projec-
tor or remote control unit to quit the service mode.
IC1841 on the main board stores the data for the ser-
vice adjustments, and should not be replaced except
for the case of defective device.
If replaced, it should be performed the re-adjustments
following to the “Electrical Adjustments”.
The data of lamp replacement monitor timer is stored
in the IC1841.
Please note that the lamp replace counter is reset
when the memory IC (IC1841) is replaced.
(Lamp replace counter can not be set to the previous
value.)
●
Caution to memory IC replacement
When IC1841 is replaced with new one, the CPU
writes down the default data of the service adjust-
ments to the replaced IC, refer to the service adjust-
ment table. As these data are not the same data as
factory shipped data, it should be required to perform
the re-adjustments following to the “Electrical
Adjustments”.
Please note that in this case the lamp replace counter
will be reset.
●
Caution of Main Board replacement (in the case
IC1841 is not defective)
When the main board is replaced, IC1841 should be
replaced with the one on previous main board. After
replacement, it should be required to perform the re-
adjustments following to the “Electrical Adjustments”.
In this case, the lamp replace counter can be kept the
value as before.
■
MEMORY IC REPLACEMENT
POWER
WARNING
LAMP
REPLACE
MENU
INPUT
SELECT
ON-OFF
Содержание PLV-Z2
Страница 39: ... 39 IC Block Diagrams BA7078AF Sync Separation IC5321 BA9743AFV IC371 ...
Страница 40: ... 40 L3E07070K0A Color Shading Correction IC401 TA1370FG Sync Separation IC5341 IC Block Diagrams ...
Страница 42: ... 42 AN5870SB PC AV SW IC5201 IC Block Diagrams ...
Страница 60: ...Mechanical Optical Parts List Accessories 60 67 61 63 64 65 66 68 69 70 72 73 73 74 75 77 76 78 79 80 ...
Страница 64: ......
Страница 80: ...Diagrams Drawings M4K Z200 ...