Optical Adjustment
Before taking optical adjustments below, remove the Cabinet Top and Main Board following to the “Mechanical
Disassemblies”
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Integrator lens or Relay lens
adjustment, you need to disconnect some connectors and FPC cables of LCD panels on the main board.
Note
:
Do not disconnect connectors on the main board, because the projector can not turn on or operate properly for
adjustment.
[Before Adjustment]
- Input a 100% of black raster signal.
[R/G/B-CONTRAST ADJUSTMENT]
1. Loosen a screw
A
on the polarized glass mounting base which
you intend to adjust.
2. Turn the polarized glass mounting base as shown in
Fig. 1
to
obtain the darkest brightness on the screen.
3. Tighten the screw
A
to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
Slot B
Polarized Glass
Mounting Base
A
1.
CONTRAST ADJUSTMENT
Fig. 1
B-Polarized Grass
Mounting Base
A
G-Polarized Grass
Mounting Base
A
R-Polarized Grass
Mounting Base
A
Fig. 2
Содержание PLV-Z2
Страница 39: ... 39 IC Block Diagrams BA7078AF Sync Separation IC5321 BA9743AFV IC371 ...
Страница 40: ... 40 L3E07070K0A Color Shading Correction IC401 TA1370FG Sync Separation IC5341 IC Block Diagrams ...
Страница 42: ... 42 AN5870SB PC AV SW IC5201 IC Block Diagrams ...
Страница 60: ...Mechanical Optical Parts List Accessories 60 67 61 63 64 65 66 68 69 70 72 73 73 74 75 77 76 78 79 80 ...
Страница 64: ......
Страница 80: ...Diagrams Drawings M4K Z200 ...