-6-
Circuit Protections
The projector will be automatically turned off when the internal temperature of the projector is abnormally high, or the
cooling fans stop spinning, or the power supplies in the projector are failed.
Warning temperature and power failure protection
the projector is shut down and the WArNING indicator lights red.
When the projector detects an abnormal condition, it is automatically shut down to protect the inside of the projector
and the WARNING indicator lights red. In this case, unplug the AC power cord and reconnect it, and then turn the
projector on once again to verify operation.
WArNING
DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD CONNECTED UNDER AN
ABNORMAL CONDITION. IT MAY RESULT IN FIRE OR ELECTRIC SHOCK.
4
Note:
- If the WARNING indicator lights red, it may defect the cooling fans or power supply circuits. Check fans operation
and power supply lines referring to the chapter “Power supply & protection circuit” and "Fan control circuit" in the
Chassis Block Diagram section.
When the temperature inside the projector reaches a certain level, the projector will be automatically shut down to
protect the inside of the projector and the WARNING and POWER indicators start blinking. When the projector has
cooled down enough (to its normal operating temperature), the POWER indicator stops blinking and lights red, The
projector can be turned on again by pressing the ON/STAND-BY button.
4
Note:
The WARNING indicator continues to blink even after the temperature inside the projector returns to normal. When
the projector is turned on again, the WARNING indicator stops blinking.
Check items
- Remove dust arround the air filter.
- Ventilation slots of the projector are blocked. In such an event, reposition the projector so that ventilation slots are
not obstructed.
- Check if projector is used at higher temperature place (Normal operating temperature is 5 to 35 ˚C or 41 to 95˚F)
the projector is shut down and the WArNING indicator is blinking red.
led indicator
WARNING
indicator
POWER
indicator
Содержание PLC-XU4000
Страница 64: ... 64 IC Block Diagrams SP3232ECYP RS 232C Driver IC3801 L3E06200P0A D A S H LCD Driver IC501 IC531 IC561 ...
Страница 65: ... 65 IC Block Diagrams L3E07111 Digital Gamma Correction IC401 TLV320AIC3105 Audio Control IC5001 ...
Страница 66: ... 66 IC Block Diagrams PW190 Scaler IC301 L3E08030F0A Dimmer Control IC9001 ...
Страница 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Страница 68: ... 68 IC Block Diagrams TPS54286 DC DC Converter IC7811 ...
Страница 73: ... 73 Parts Location Diagrams KA2 XU400000 L09 M12 Relay lens Out assembly S06 ...
Страница 96: ... KA2AC March 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...