-31-
Electrical Adjustments
1. Enter the service mode.
2. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”, item
no. “
0
” and change data value to adjust voltage to be
4.0 ±0.1V
.
3. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
4. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select item no. “
2
” and change
data value to adjust voltage to be
5.2 ±0.1V
.
5. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
6. Connect a digital voltmeter to test point “
tPFANc
” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be
3.5 ±0.1V
.
7. Connect a digital voltmeter to test point “
tPFANc
” (+)
and chassis ground (-). Select item no. “
5
” and change
data value to adjust voltage to be
12 ±0.1V
.
1. Fan control adjustment
Gain adjustment [Pc]
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal with
computer1 [rGB]
mode.
3. Connect an oscilloscope to test point “
tP35G
” (+) and
chassis ground (-).
4. Select group no. “
0
”, item no. “
3
” and adjust the ampli-
tude “
a
” to be minimum by changing the Data value.
5. Connect an oscilloscope to test point “
tP35r
” (+) and
chassis ground (-).
6. Select group no. “
0
”, item no. “
4
” and adjust the ampli-
tude “
a
” to be minimum by changing the Data value.
7. Connect an oscilloscope to test point “
tP35B
” (+) and
chassis ground (-).
8. Select group no. “
0
”, item no. “
5
” and adjust the ampli-
tude “
a
” to be minimum by changing the Data value.
(a)
White Level
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal with
computer1 [rGB]
mode.
3. To start the auto-calibration for PC adjustment, select
group no. “
260
”, item no. “
0
” and then change data
value from “
0
” to “
1
”. After the auto-calibration com-
pleted, "OK" will appear on the screen.
2. Auto calibration adjustment [Pc]
Below adjustments are performed when the above auto
calibration is failed.
Pedestal adjustment [Pc]
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal with
computer1 [rGB]
mode.
3. Connect an oscilloscope to test point “
tP35G
” (+) and
chassis ground (-).
4. Select Group No. “
0
”, Item No. “
0
” and change data
value to adjust the black level to be minimum.
5. Connect an oscilloscope to test point “
tP35r
” (+) and
chassis ground (-).
6. Select Item No. “
1
” and change data value to adjust the
black level to be minimum.
7. Connect an oscilloscope to test point “
tP35B
” (+) and
chassis ground (-).
8. Select Item No. “
2
” and change data value to adjust the
black level to be minimum.
Blac
k Lebel
Adjustments item no. [2] and [4] are carried out
at the spare parts shipment in the factory, there-
fore they are not required when the main board is
replaced with new one.
Содержание PLC-XU4000
Страница 64: ... 64 IC Block Diagrams SP3232ECYP RS 232C Driver IC3801 L3E06200P0A D A S H LCD Driver IC501 IC531 IC561 ...
Страница 65: ... 65 IC Block Diagrams L3E07111 Digital Gamma Correction IC401 TLV320AIC3105 Audio Control IC5001 ...
Страница 66: ... 66 IC Block Diagrams PW190 Scaler IC301 L3E08030F0A Dimmer Control IC9001 ...
Страница 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Страница 68: ... 68 IC Block Diagrams TPS54286 DC DC Converter IC7811 ...
Страница 73: ... 73 Parts Location Diagrams KA2 XU400000 L09 M12 Relay lens Out assembly S06 ...
Страница 96: ... KA2AC March 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...