-59-
Troubleshooting
No Power
lamp cover switch
Make sure that the lamp cover is mounted correctly. If not
or the lamp cover removed, the lamp does not light on for
the safety. Check the lamp cover and lamp cover switch
(SW901).
-
When all of led indicators are not lighting
, the symptom indicates that the primary power supply circuit does
not operate properly. Check the power primary circuit and parts as follow;
AC cord, F601 (Fuse), Power board,
SW902 (Thermal sw.) short in normal
SW902 opens when the surrounding temperature of the switch exceeds 115°C.
This projector provides a function which can be specified a defective area simply by indicating the LEDs. Connect the
AC cord and press the Power button once and then check the LED indication.
-
When the WArNING (red) and PoWer (red) indicators are flashing
, the symptom indicates that the projector
detected an abnormal temperature risen inside the projector. Check the air filters and remove the object near the
intake and exhaust fan openings, and wait until the POWER indicator stops flashing, and then try to turn on the
projector.
The internal temperature is monitored by sensor ICs, IC8831, IC8821 on the Main board and IC8811 on
the R/C board.
-
When the WArNING indicator lights red
, the symptom indicates that the projector detected an abnormality in
the cooling fan operation or in the power supply secondary circuits. Check fan operation and power supply lines,
and the driving signal status.
The P_FAIL signal (Error: L), FAN_ERR_B signal (Error: L), FAN_ERR_C signal (Error: H) are sent to pins 215,
267 and 29 of IC301<SYSTEM CONTROL> respectively when the abnormality occurred inside the projector,
and then the IC301 sends the shutdown signal, LAMP_DC_ON, to the power supply circuit to stop its operation,
and signal SCIOUT to the lamp ballast board via IC9886 and SW901<lamp cover switch> to stop operation of
the lamp circuit.
An abnormality occurs on the secondary power supply;
Check power supplies S16.5V, S6V, S-7V. P_FAIL signal becomes Low when the abnormality occurs on
any of the power supply lines.
An abnormality occurs on the fan control circuit;
If fans FN901, FN902 or FN903 has an error, the FAN_ERR and P_FAIL signals become "L". If fans FN904
or FN905 has an error, the FAN_ERR and F_FAIL signals become "L". If fan FN906 has an error, the
FAN_ERR_C signal becomes "H". The FAN_ERR signal is sent to lamp ballast board to stop lamp circuit.
An abnormality occurs on the drive signals;
ON_15V signal (Power-on: H) is output from pin 94 of IC301 and switches IC592,15.5V_PNL supply circuit,
ON_3.3V signal (Power-on: H) is output from pin 93 of IC301 and switches IC5621, 1.0V, Q3582, 3.3V and
3.3VGAM power supply.
LAMP_DC_ON signal (Power-on: H) is output from pin 89 of IC301 and supplied to the PFC Control IC,
IC621, on the power supply board.
SCIOUT signal (Power-on: H) is output from pin 23 of IC9001 and applied to pin 2 of IC9886 and output
pin 4 and then supplied to the lamp ballast board through SW901<Lamp Cover SW>.
LAMP_DET signal at the pin 285 of IC301 is applied from the lamp ballast unit. If the abnormality occurred
on the lamp ballast unit, LAMP_DET signal becomes “High” and then IC301 shuts down the power supply
circuit.
Содержание PLC-XU4000
Страница 64: ... 64 IC Block Diagrams SP3232ECYP RS 232C Driver IC3801 L3E06200P0A D A S H LCD Driver IC501 IC531 IC561 ...
Страница 65: ... 65 IC Block Diagrams L3E07111 Digital Gamma Correction IC401 TLV320AIC3105 Audio Control IC5001 ...
Страница 66: ... 66 IC Block Diagrams PW190 Scaler IC301 L3E08030F0A Dimmer Control IC9001 ...
Страница 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Страница 68: ... 68 IC Block Diagrams TPS54286 DC DC Converter IC7811 ...
Страница 73: ... 73 Parts Location Diagrams KA2 XU400000 L09 M12 Relay lens Out assembly S06 ...
Страница 96: ... KA2AC March 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...