-27-
Electrical Adjustments
1. Receive the 16-step grey scale computer signal with
Computer [Analog RGB]
mode.
2. Enter the service mode.
3. Connect a digital voltmeter to test point “
TP505R
”
(+) and chassis ground (-).
4. Select item no. “
1
and adjust the voltage to be
7.50
±0.1Vdc by changing the Data value.
5. Connect a digital voltmeter to test point “
TP503G
”
(+) and chassis ground (-).
6. Select item no. “
2
” and adjust the voltage to be
7.50
±0.1Vdc by changing the Data value.
7. Connect a digital voltmeter to test point “
TP501B
”
(+) and chassis ground (-).
8. Select item no. “
3
” and adjust the voltage to be
7.50
±0.1Vdc by changing the Data value.
x
Signal Center adjustment
1. Receive the 16-step gray scale computer signal with
Computer [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP3501
” (+)
and chassis ground (-).
4. Select item no. “
22
” and adjust the amplitude “a” to be
9.5
±0.1V by changing the Data value.
5. Select item no. “
23
” and adjust the amplitude “b” to be
1.0
±0.1V by changing the Data value.
(a)
(b)
c
PSIG adjustment
1. Receive the 16-step gray scale computer signal with
Computer [Analog RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP505R
” (+)
and chassis ground (-).
4. Select item no. “
4
” and adjust the amplitude “a” to be
minimum by changing the Data value.
5. Connect an oscilloscope to test point “
TP503G
” (+)
and chassis ground (-).
6. Select item no. “
5
” and adjust the amplitude “a” to be
minimum by changing the Data value.
7. Connect an oscilloscope to test point “
TP501B
” (+)
and chassis ground (-).
8. Select item no. “
6
” and adjust the amplitude “a” to be
minimum by changing the Data value.
(a)
White Level
v
Gain adjustment [PC]
1. Receive the 16-step gray scale composite video sig-
nal with
Video [Video]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP505R
” (+)
and chassis ground (-).
4. Select item no. “
4
” and adjust the amplitude “a” to be
minimum by changing the Data value.
5. Connect an oscilloscope to test point “
TP503G
” (+)
and chassis ground (-).
6. Select item no. “
5
” and adjust the amplitude “a” to be
minimum by changing the Data value.
7. Connect an oscilloscope to test point “
TP501B
” (+)
and chassis ground (-).
8. Select item no. “
6
” and adjust the amplitude “a” to be
minimum by changing the Data value.
(a)
White Level
b
Gain adjustment [Video]
Содержание PLC-XU40
Страница 50: ... 50 IC Block Diagrams AD8075 Selector IC201 AD8183ARU Selector IC1201 AN7513 Audio Amp IC5001 ...
Страница 51: ... 51 AN5870SB RGB SW IC5201 IC Block Diagrams AD9884AKS A D IC8201 ...
Страница 54: ... 54 IC Block Diagrams CXD3526GG LCD Driver Timing Generator IC401 FA5502 P F Control IC611 ...
Страница 55: ... 55 LA7217 Sync Separator IC5361 M62392 D A IC3561 IC Block Diagrams ...
Страница 56: ... 56 NJM2284M Switch IC2101 IC Block Diagrams M62393 D A IC281 IC7801 ...
Страница 57: ... 57 PW164B 10 System Control Scan Converter IC301 IC Block Diagrams STR Z2156 Power Switching Control IC631 ...
Страница 82: ...MA3 XU4000 Electrical Parts List 82 Key No Part No Description Key No Part No Description ...
Страница 84: ...MA3 XU4000 84 47 44 44 47 44 44 Mechanical Parts List 47 57 56 47 47 Optical Parts ...
Страница 85: ...MA3 XU4000 85 44 44 54 67 Red 68 Green 69 Blue 45 45 45 Mechanical Parts List ...
Страница 86: ...MA3 XU4000 86 43 43 53 d Green Blue 61 44 44 47 43 47 53 Mechanical Parts List 53 a Red 53 b Green 53 c Blue ...
Страница 87: ...MA3 XU4000 87 52 a 52 46 46 46 46 52 Mechanical Parts List ...
Страница 88: ...MA3 XU4000 88 Mechanical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Страница 90: ... MA3A Jan 2003 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 107: ...1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L A10 15 Schematic Diagrams PLC XU40 A10 Left ...
Страница 108: ...9 10 11 12 13 14 15 16 A B C D E F G H I J K SCH_MA3A 16 Schematic Diagrams PLC XU40 A10 Right ...
Страница 115: ...Diagrams Drawings MA3 XU4000 ...