background image

PLC-XU305A/355A Expand Serial Command Functional Specifications 

                                                                                   

                                                                               

65/68 

9.12  Other Status Read Command 

9.12.1  CR_STATUS Command 

Command  “CR_STATUS”(CR) 

Details 

Get status of Projector behavior. 
This command  affects the same as ”CR0” of Basic Serial command, but this has 
an error code. 

Response 

Acceptable 

“000_%1”[CR] 

%1 

“00”= Power ON 
“80”= Stand by 
“40”= Count down 
“20”= Cooling down 
“10”= Power failure 
“28”= Cooling down due to abnormal temperature 
“88”= Stand by after Cooling down 
“24”= Power saving cooling down 
“04”= Power saving 
“21”= Cooling down due to Lamp failure 
“81”= Stand by after Cooling down due to Lamp failure 

Unacceptable  “Error Code”[CR] 

 

9.12.2  CR_SIGNAL Command 

Command  “CR_SIGNAL”(CR) 

Details 

Get Signal status if there is signal or not 

Response 

Acceptable 

“000_%a”[CR] 

%a 

“ON” ------------------------ Signal is found 
“OFF” ----------------------- There is no signal 

Unacceptable  “Error Code” [CR] 

 

9.12.3  CR_VMUTE Command 

Command  “CR_VMUTE”[CR] 

Details 

Get setting status of No Show 

Response 

Acceptable 

“000_%a”[CR] 

%a 

“ON” -------- No Show is ON, User Logo (My picture) is displayed 
“OFF” ------- No Show is OFF 

Unacceptable  “Error Code” [CR] 

 

9.12.4  CR_FREEZE Command 

Command  “CR_FREEZE”[CR] 

Details 

Get setting status of Freeze 

Response 

Acceptable 

“000_%a”[CR] 

%a 

“ON” ---------------------- Freeze is ON 
“OFF” --------------------- Freeze is OFF 

Unacceptable  “Error Code” [CR] 

 

Содержание PLC-XU305A

Страница 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC XU305A PLC XU355A Ver 1 00 SANYO Electric Co Ltd DS Company Projector Division ...

Страница 2: ...mand Table 12 6 1 Image Status Read Command Table 12 6 2 PC Adjust Status Read Command Table 12 6 3 Video Status Read Command Table 12 6 4 Input Status Read Command Table 12 6 5 Screen Status Read Command Table 13 6 6 Lamp Status Read Command Table 13 6 7 Sound Status Read Command Table 13 6 8 Setting Status Read Command Table 13 6 9 Other Status Read Command 14 7 Error Code Table 15 8 Functional ...

Страница 3: ...d 24 8 6 1 CF_INPUT Command 24 8 6 2 CF_SOURCE Command 24 8 6 3 CF_INPUT1 Command 25 8 6 4 CF_INPUT2 Command 25 8 6 5 CF_INPUT3 Command 25 8 6 6 CF_INPUT4 Command 25 8 6 7 CF_INPUT5 Command 25 8 6 8 CF_INPUT_ 1_ 2 Command 26 8 6 9 CF_SYSTEM Command 27 8 7 Screen Control Command 28 8 7 1 CF_SCREEN Command 28 8 7 2 CF_DZCENT Command 28 8 7 3 CF_KEYSTONE Command 28 8 7 4 CF_KYSTNMODE Command 29 8 7 5...

Страница 4: ...nd 37 8 10 16 CF_STANDBYMODE Command 37 8 10 17 CF_CCAPTIONDISP Command 37 8 10 18 CF_CCAPTIONCOLOR Command 38 8 10 19 CF_RCODE Command 38 8 10 20 CF_KEYDIS Command 38 8 10 21 CF_PJPINCODE Command 39 8 10 22 CF_FANMODE Command 39 8 10 23 CF_FANCONTROL Command 39 8 10 24 CF_FILTIMER Command 40 8 10 25 CF_FILH Command 40 8 10 26 CF_FDEFAULT Command 40 8 11 Other Command 41 8 11 1 CF_KEYENU Command 4...

Страница 5: ...CLAMP Command 47 9 5 4 CR_H POS Command 47 9 5 5 CR_V POS Command 48 9 5 6 CR_DDOTS Command 48 9 5 7 CR_DLINE Command 48 9 5 8 CR_PCSTORE Command 48 9 6 Video Status Read Command 49 9 6 1 CR_SERSYS Command 49 9 7 Input Status Read Command 50 9 7 1 CR_INPUT Command 50 9 7 2 CR_SOURCE Command 50 9 7 3 CR_SRCINP1 Command 50 9 7 4 CR_SRCINP2 Command 50 9 7 5 CR_SRCINP3 Command 50 9 7 6 CR_SRCINP4 Comm...

Страница 6: ...and 59 9 11 3 CR_AUTOSETUPKEYSTONE Command 59 9 11 4 CR_INPUTSEARCH Command 59 9 11 5 CR_BACKGND Command 60 9 11 6 CR_DISP Command 60 9 11 7 CR_LOGO Command 60 9 11 8 CR_CEIL Command 60 9 11 9 CR_REAR Command 60 9 11 10 CR_POINTER Command 61 9 11 11 CR_P MANE Command 61 9 11 12 CR_P MANETIME Command 61 9 11 13 CR_ON STA Command 61 9 11 14 CR_STANDBYMODE Command 61 9 11 15 CR_CCAPTIONDISP Command 6...

Страница 7: ... 7 68 9 12 Other Status Read Command 65 9 12 1 CR_STATUS Command 65 9 12 2 CR_SIGNAL Command 65 9 12 3 CR_VMUTE Command 65 9 12 4 CR_FREEZE Command 65 9 12 5 CR_PTIMER Command 66 9 12 6 CR_TEMPWARN Command 66 9 12 7 CR_TEMP Command 67 9 12 8 CR_TEMPFAIL Command 68 ...

Страница 8: ... commands are defined as Expand Serial Commands 2 Serial Interface Specification 2 1 Transfer Specification Item Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Control N A Note1 Transmission Speed initial setting value is 19200 Note2 Transmission Speed can be changed in service mode 2 2 Connection Dedicated serial cable must...

Страница 9: ...tor CF_BRIGHT_032 CR Next Command Projector PC 000 CR Response A few ms 5s When a computer sends next command before receiving a response the projector may not operate properly except when there is no response for more than 5 seconds 5 It takes about 5 seconds for internal initialization after plugging in AC power During this time commands cannot be processed Do not issue any command 4 Name Defini...

Страница 10: ...OS_ 1 CR Set Vertical Position value CF_DDOTS_ 1 CR Set Display Dots value CF_DLINE_ 1 CR Set Display Line value CF_PCSTORE_ 1 CR Store current values of PC Adjust at Mode 1 5 CF_PCMODEFREE_ 1 CR Release registered values of Mode1 5 5 3 Input Control Command Table Execute command Item CF_INPUT_ 1 CR Select Input CF_SOURCE_ 1 CR Select Input Source CF_INPUT1 _ 1 CR Select computer 1 and set Input s...

Страница 11: ... Set Rear function CF_POINTER_ 1 CR Set Pointer mode CF_P MANE_ 1 CR Set Power management function CF_P MANETIME_ 1 CR Set Power management time CF_ON STA_ 1 CR Set Power ON Start function CF_STANDBYMODE_ 1 CR Set Standby Mode CF_CCAPTIONDISP_ 1 CR Set channel of Closed caption CF_CCAPTIONCOLOR_ 1 CR Set color of Closed caption CF_RCODE_ 1 CR Select Remote Control Reception Code CF_KEYDIS_ 1 CR Di...

Страница 12: ... CR Get setting value of Total Dots CR_CLAMP CR Get setting value of Clamp CR_H POS CR Get setting value of Horizontal Position CR_V POS CR Get setting value of Vertical Position CR_DDOTS CR Get setting value of Display Dots CR_DLINE CR Get setting value of Display Line CR_PCSTORE CR Get Free or Stored status for PC Adj mode1 5 6 3 Video Status Read Command Table Status read command Item CR_SERSYS...

Страница 13: ...UTOSETUPPCADJ Get setting status of Auto PC in Auto setup CR_AUTOSETUPKEYSTONE Get setting status of Keystone in Auto setup CR_INPUTSEARCH CR Get setting status of Input search CR_BACKGND CR Get setting status screen mode for the case of no signal CR_DISP CR Get setting status of Display CR_LOGO CR Get setting status of Logo CR_CEIL CR Get setting status of Ceiling CR_REAR CR Get setting status of...

Страница 14: ..._SIGNAL CR Get Signal Status if there is a signal or not CR_VMUTE CR Get setting status of No Show CR_FREEZE CR Get setting status of Freeze CR_PTIMER CR Get the operating status of Presentation Timer CR_TEMPWARN CR Get if temperature is close to abnormal temperature CR_TEMP CR Get current temperature status CR_TEMPFAIL CR Get temperature when sensors approach abnormal temperature ...

Страница 15: ...command for Optional function which is not installed 201 When reached upper or lower limit of increasing or decreasing data 301 Command cannot be executed during capturing display Resend the command after a while 302 Command cannot be executed during Auto PC operation Resend the command after a while 303 Command cannot be executed while Memory Card Viewer is in process Resend the command after a w...

Страница 16: ..._1344 CR PC PJ 000 CR Acceptable 8 3 Operation Requirements 1 Functional Execution Command is limited when the projector status is as below However Status Read Command is effective even under these conditions Projector Status Available Functional Execution Command Standby Mode C00 POWER ON Countdown in process C00 POWER ON Terminates Countdown C01 POWER OFF C02 POWER OFF Terminates Countdown Cooli...

Страница 17: ...rns to original setting The value is held in Suspend mode This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly select Color setting value UP Current Color setting value 1 DN Current Color setting value 1 Details Set Color value of user control The value set by this command will not...

Страница 18: ...lue 1 Details Set Gamma value of user control The value set by this command will not be saved to projector Therefore when turning into Standby mode or ALL is OFF the value returns to original setting The value is held in Suspend mode This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_WBAL 1_ 2 CR 1 R Red G Gree...

Страница 19: ...ve scan The value set by this command will not be saved to projector Therefore when turning into Standby mode or ALL is OFF the value returns to original setting The value is held in Suspend mode This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 10 CF_NZRED Command Command CF_NZRED_ 1 CR 1 OFF Cancel Noise Reduction L1 Noise Reduction for...

Страница 20: ... Details Select Image Mode Parameter CUSTOM1 to CUSTOM4 is the same as Image1 to Image4 displayed when selecting Image on OSD menu The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 12 CF_IMAGEADJ Command Command CF_IMAGEADJ_ 1 CR 1 RST Res...

Страница 21: ...alue which is not over 140MHz UP Current Total Dots setting value 1 DN Current Total Dots setting value 1 Details Set Total Dots of PC signal The value set by this command will not be saved to projector Therefore when turning into Standby mode or ALL is OFF the value returns to original setting This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable 101 CR when ...

Страница 22: ...Vertical Position setting value 1 DN Current Vertical Position setting value 1 Details Set Vertical Position value of PC signal The value set by this command will not be saved to projector Therefore when turning into Standby mode or ALL is OFF the value returns to original setting This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable 101 CR When Input source i...

Страница 23: ...ent PC Adjust status to Mode2 MODE3 Store current PC Adjust status to Mode3 MODE4 Store current PC Adjust status to Mode4 MODE5 Store current PC Adjust status to Mode5 Details Store current PC Adjust status each parameter status such as Total dots to Mode1 Mode5 This command operates the same way as storing to Mode1 Mode5 in PC Adjust MENU This command is available in normal Power ON status Respon...

Страница 24: ...lect Scart Input UP Switch Input as follows Analog YPBPR Scart DN Switch Input as follows Scart YPBPR Analog Input is Computer 2 DIGITAL Select DVI Input HDCP Select DVI HDCP Input ANALOG Select Analog Input UP Switch Input as follows DIGITAL HDCP ANALOG DIGITAL DN Switch Input as follows ANALOG HDCP DIGITAL ANALOG Input is Video VIDEO Select Composite Video Input UP DN Although there is no option...

Страница 25: ...by 1 at the same time This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 6 5 CF_INPUT3 Command Command CF_INPUT3_ 1_ CR 1 VIDEO Select Composite video Input Details Select Video input This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 6 6 CF_INPUT4 Command Command CF_INPUT4_ 1_ CR 1 S ...

Страница 26: ... is COMPUTER1 ANALOG Select Analog RGB Input YPBPR Select Component SCART Select SCART When 1 is COMPUTER2 DIGITAL Select DVI Input HDCP Select DVI HDCP Input ANALOG Select Analog RGB Input When 1 is VIDEO VIDEO Select Video Input When 1 is S VIDEO S VIDEO Select S Video Input Details Select Input specified by 1 and also Source specified by 2 at once This command is available in normal Power ON st...

Страница 27: ...m Auto NTSC Select NTSC NTSC443 Select NTSC4 43 PAL Select PAL SECAM Select SECAM PAL M Select PAL M PAL N Select PAL N 1080I Select 1080i 1035I Select 1035i 720P Select 720p 575P Select 575p 480P Select 480p 575I Select 575i 480I Select 480i Details Select System of currently selected Input When Input specified by 1 is inappropriate for selected Input the projector returns 101 CR and the command ...

Страница 28: ...rmal Power ON status Note When Input is computer and AV sorts signals 480i 575i etc are entered the signal recognized as Video Input Response Acceptable 000 CR Unacceptable Error Code CR 8 7 2 CF_DZCENT Command Command CF_DZCENT_ 1 CR 1 CENT Cancel Digital Zoom CENT CENTER Details Cancel Digital Zoom When image is expanded or shrunk reset its value This command is available in normal Power ON stat...

Страница 29: ...atus Note1 When Screen setting is not in Custom mode projector changes image mode into Custom by receiving this command Note2 When there is no signal detected projector returns 101 and the command does not execute Response Acceptable 000 CR Unacceptable Error Code CR 8 7 6 CF_VPOS Command Command CF_VPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Vertical Position setting val...

Страница 30: ...re is no signal detected projector returns 101 and the command does not execute Response Acceptable 000 CR Unacceptable Error Code CR 8 7 8 CF_HPOS Command Command CF_HPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Horizontal Position setting value 1 DN Horizontal Position setting value 1 Details Set Horizontal Position This command is available in normal Power ON status Note...

Страница 31: ... EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 8 2 CF_LAMPLIFECONTRL Command Command CF_LAMPLIFECONTRL_ 1 CR 1 MODE1 Set Lamp life mode to Mode1 MODE2 Set Lamp life mode to Mode2 Details Select Lamp life mode The value set by this command is stored in EEPROM and its setting is ef...

Страница 32: ...r and RC and directly select Volume setting value When setting Volume value the Sound Mute ON status is canceled just like RC operation The value set by this command is stored in Projector This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 9 2 CF_MUTE Command Command CF_MUTE_ 1 CR 1 ON Set Sound Mute to ON OFF Set Sound Mute to OFF Details C...

Страница 33: ...CF_MENUPOSITION_ 1 CR 1 SET Move the menu display to next position Details Change the menu position This command is available in normal Power ON status The language set by this command is stored in EEPROM and its setting is effective after ALL is OFF Position top left top right center bottom left bottom right top left Menu display appears with the first command when menu display is not shown on th...

Страница 34: ...lable in normal Power ON status Note It is unable to set Keystone PC ADJ and Input search to OFF at once e g If projector receives Input search OFF command while Auto PC ADJ and Keystone are OFF it returns error code 101 Response Acceptable 000 CR Unacceptable Error Code CR 8 10 6 CF_AUTOSETUP Command CF_AUTOSETUP_ 1 CR 1 START Execute Auto Setup Details Execute Auto Setup Note CF commands does no...

Страница 35: ...ng in positive order OFF DFLT User OFF DN Switch Logo setting in negative order OFF User DFLT OFF Details Set Cancel Logo The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status 1 Set LOGO PIN CODE When LOGO LOCK is in operation PIN CODE is correct Command is valid Acceptable PIN CODE is incorrect Comm...

Страница 36: ...able 000 CR Unacceptable Error Code CR 8 10 12 CF_POINTER Command Command CF_POINTER_ 1 CR 1 SPOTLIGHTMAX Select Maximum Spotlight SPOTLIGHTMID Select Medium Spotlight SPOTLIGHTMIN Select Minimum Spotlight ARROW Select Arrow FINGER Select Finger mark LASER Select Laser mark Details Select Pointer style This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Erro...

Страница 37: ...ng is effective after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 16 CF_STANDBYMODE Command Command CF_STANDBYMODE_ 1 CR 1 ECO Small standby electricity NORMAL Normal standby electricity Selecting NETWORK Details Switch Standby Mode setting This command is available in normal Power ON status Response Acceptable 000 CR Un...

Страница 38: ...R 1 001 Select Code1 002 Select Code2 003 Select Code3 004 Select Code4 005 Select Code5 006 Select Code6 007 Select Code7 008 Select Code8 UP Switch Code setting of Remote Control forward Code1 Code2 Code3 Code8 Code1 DN Switch Code setting of Remote Control backward Code8 Code7 Code6 Code1 Code8 Details Select Code of Remote Control The status set by this command is stored in EEPROM and its sett...

Страница 39: ...ime lamp turns on Response Acceptable 000 CR Unacceptable Error Code CR 8 10 22 CF_FANMODE Command Command CF_FANMODE_ 1 CR 1 L1 Set Fan Mode to L1 L2 Set Fan Mode to L2 Details Switch Fan Mode When L1 is selected fan noise after POWER OFF is louder When L2 is selected fan noise after POWER OFF becomes quiet however fan rotates longer than L1 The status set by this command is stored in EEPROM and ...

Страница 40: ...0 200 100 Details Set timer of Filter replacement clean up warning display Response Acceptable 000 CR Unacceptable Error Code CR 8 10 25CF_FILH Command Command CF_FILH_ 1 CR 1 RST Reset Filter used time Details Reset filter used time Response Acceptable 000 CR Unacceptable Error Code CR 8 10 26CF_FDEFAULT Command Command CF_FDEFAULT_ 1 CR 1 RST Details Set the value to Factory Default This command...

Страница 41: ...nacceptable Error Code CR 8 11 2 CF_MENU Command Command CF_MENU_ 1 CR 1 ON Display OSD Menu OFF Cancel OSD menu Details Display Cancel On Screen Display Menu This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 3 CF_POWER Command Command CF_POWER_ 1 CR 1 ON Power ON projector OFF Power OFF Projector Note1 Count down can be terminated by se...

Страница 42: ...ower ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 5 CF_VMUTE Command Command CF_VMUTE_ 1 CR 1 ON Set No show ON OFF Set No show OFF UP Switch setting On Off On DN Switch setting On Off On Note UP and DN behave the same Details Set Cancel No show setting This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 6 CF_PTIMER...

Страница 43: ...character line as the required data 000 1 CR 1 Required Data Character Line See Basic Status Read Command Table 3 When the received data cannot be decoded the projector returns CR 9 2 Transfer Example Get total dots of projector by Expand Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR 9 3 Operation Condition 1 Basically Status Read Commands should be always operated 2 Status Read Commands are invali...

Страница 44: ...3 Unacceptable Error Code CR 9 4 3 CR_COLOR Command Command CR_COLOR CR Details Get Color value of user control Response Acceptable 000_ a CR a 000 063 Unacceptable Error Code CR 9 4 4 CR_TINT Command Command CR_TINT CR Details Get Tint value of user control Response Acceptable 000_ a CR a 000 063 Unacceptable Error Code CR When the command is invalid due to condition such as Input source CR When ...

Страница 45: ...AL G Command Command CR_WBAL G CR Details Get White Balance Green value of user control Response Acceptable 000_ a CR a 000 063 Unacceptable Error Code CR 9 4 9 CR_WBAL B Command Command CR_WBAL B CR Details Get White Balance Blue value of user control Response Acceptable 000_ a CR a 000 063 Unacceptable Error Code CR 9 4 10 CR_COLTEMP Command Command CR_COLTEMP CR Details Get Color Temp setting v...

Страница 46: ...d OFF Progressive scan is disabled Unacceptable Error Code CR 9 4 13 CR_IMAGE Command Command CR_IMAGE CR Details Get image setting status Required data CUSTOM1 to CUSTOM4 is the same as Image1 to Image4 displayed when selecting IMAGE on OSD menu Response Acceptable 000_ a CR a DYNAMIC Dynamic STAND Standard REAL Real CINEMA Cinema BLACKBOARD Blackboard COLORBOARD Colorboard CUSTOM1 CUSTOM4 Image1...

Страница 47: ...um value depends on input signal Unacceptable Error Code CR When the command is invalid due to condition such as Input source CR When unclear command is received 9 5 3 CR_CLAMP Command Command CR_CLAMP CR Details Get Clamp value Response Acceptable 000_ a CR a 0001 nnnn nnnn depends on input signal Unacceptable Error Code CR When the command is invalid due to condition such as Input source CR When...

Страница 48: ...d is invalid due to condition such as Input source CR When unclear command is received 9 5 7 CR_DLINE Command Command CR_DLINE CR Details Get Display Line value Response Acceptable 000_ a CR a 0100 nnnn nnnn Total Line Vertical Position value Unacceptable Error Code CR When the command is invalid due to condition such as Input source CR When unclear command is received 9 5 8 CR_PCSTORE Command Com...

Страница 49: ...urns auto detected signal in Auto mode Only available for Video input N A when Input is computer Response Acceptable 000_ a CR a 1080I60 1080i 60Hz 1080I50 1080i 50Hz 1035I 1035i 720P 720p 575P 575p 480P 480p 575I 575i includes Composite signal such as PAL 480I 480i includes Composite signal such as NTSC NO_SIGNAL There is no signal Unacceptable 101 CR When Input for PC is selected CR ...

Страница 50: ...elected NETWORK Network is selected Unacceptable Error Code CR 9 7 3 CR_SRCINP1 Command Command CR_SRCINP1 CR Details Get selected source of Input 1 Response Acceptable 000_ 1 CR Request data ANALOG Analog RGB Input is selected YPBPR YPBPR Input is selected SCART Scart Input is selected Unacceptable Error Code CR 9 7 4 CR_SRCINP2 Command Command CR_SRCINP2 CR Details Get selected source of Input 2...

Страница 51: ...selected source of Input 4_S video Response Acceptable 000_ 1 CR Request data S VIDEO S Video Input is selected Unacceptable Error Code CR 9 7 7 CR_SRCINP4 Command Command CR_SRCINP5 CR Details Get selected source of Input 5_Network Response Acceptable 000_ 1 CR Request data NETWORK Network is selected Unacceptable Error Code CR ...

Страница 52: ...selected D 1035I D 1035i is selected D 720P D 720p is selected D 575P D 575p is selected D 480P D 480p is selected When there is no signal projector returns error code 101 CR Input is Y Pb Cb Pr Cr AUTO Auto is selected 1080i 1080i is selected 1035i 1035i is selected 720p 720p is selected 575p 575p is selected 480p 480p is selected 575i 575i is selected 480i 480i is selected Projector returns sele...

Страница 53: ... 1080i is selectable 1035I 1035i is selectable 575I 575i is selectable 480I 480i is selectable Projector does not return Error Code 101 even if there is no signal When Input is Video S Video Returns all the System titles on Menu including Auto AUTO Auto is selectable PAL PAL is selectable SECAM SECAM is selectable PAL N SECAM is selectable Projector does not return Error Code 101 even if there is ...

Страница 54: ... is invalid due to condition such as Input source CR When unclear command is received 9 8 2 CR_ KYSTNMODE Command Command CR_KYSTNMODE CR Details Get setting status of Keystone Store Mode Response Acceptable 000_ a CR a STR Store mode is Store RST Store mode is Reset Unacceptable Error Code CR 9 8 3 CR_VSCALE Command Command CR_VSCALE CR Details Get setting status of Vertical Scale Store Mode Resp...

Страница 55: ...pand Serial Command Functional Specifications 55 68 9 8 6 CR_HPOS Command Command CR_HPOS CR Details Get setting status of Horizontal Position Store Mode Response Acceptable 000_ 1 CR 1 15 015 Unacceptable Error Code CR ...

Страница 56: ... time Unacceptable Error Code CR 9 9 2 CR_LAMPH Command Command CR_LAMPH CR Details Get total running time of lamp by hour h Actual running time not corresponding value Response Acceptable 000_ 1 CR 1 00000 99999 Unacceptable Error Code CR 9 9 3 CR_LAMPCORRESPH Command Command CR_LAMPCORRESPH CR Details Get total running time of lamp by hour h Corresponding value not actual running time Response A...

Страница 57: ... lamps model and No 1 Lamp is ON and No 2Lamp is OFF 4IOXI 4 lamps model and No 1 No 4 lamps are ON No 2 lamp is OFF and No 3 model is failed Unacceptable Error Code CR 9 9 6 CR_PROJH Command Command CR_PROJH CR Details Get total running time of Projector by hour h Response Acceptable 000_ 1 CR 1 0000000 0099999 Unacceptable Error Code CR 9 9 7 CR_HMLAMP Command Command CR_HMLAMP CR Details Get la...

Страница 58: ... Command Command CR_VOLUME CR Details Get Volume value of user control Response Acceptable 000_ a CR a 000 063 Unacceptable Error Code CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Get sound mute setting status Response Acceptable 000_ a CR a ON Sound Mute is ON OFF Sound Mute is OFF Unacceptable Error Code CR ...

Страница 59: ...cted THA Thai is selected Unacceptable Error Code CR 9 11 2 CR_AUTOSETUPPCADJ Command Command CR_AUTOSETUPPCADJ CR Details Get Auto PC adj setting status in Auto setup Response Acceptable 000_ a CR a ON Auto PC ADJ in Auto setup is ON OFF Auto PC ADJ in Auto setup is OFF Unacceptable Error Code CR 9 11 3 CR_AUTOSETUPKEYSTONE Command Command CR_AUTOSETUPKEYSTONE CR Details Get Keystone setting stat...

Страница 60: ... Display is ON OFF Display is OFF CNTDWNOFF Countdown OFF Unacceptable CR 9 11 7 CR_LOGO Command Command CR_LOGO CR Details Get setting status of Logo Response Acceptable 000_ 1 CR 1 OFF Logo function is OFF DFLT Default Logo is selected USER User Logo is selected Unacceptable CR 9 11 8 CR_CEIL Command Command CR_CEIL CR Details Get setting status of Ceiling Response Acceptable 000_ 1 CR 1 ON Ceil...

Страница 61: ... a OFF Power Management is OFF READY Power Management is Ready SHUTDOWN Power Management is set to Shut Down mode Unacceptable Error Code CR 9 11 12 CR_P MANETIME Command Command CR_P MANETIME CR Details Get time to start Power Management Response Acceptable 000_ a CR a 001 030 1 minute to 30 minutes Unacceptable Error Code CR 9 11 13 CR_ON STA Command Command CR_ON STA CR Details Get Power ON Sta...

Страница 62: ...cceptable 000 CR a COLOR Color is selected WHITE White is selected Unacceptable Error Code CR 9 11 17 CR_RCODE Command Command CR_RCODE CR Details Get selected Remote Control Code Response Acceptable 000_ a CR a 001 Code1 is selected 002 Code2 is selected 003 Code3 is selected 004 Code4 is selected 005 Code5 is selected 006 Code6 is selected 007 Code7 is selected 008 Code8 is selected Unacceptable...

Страница 63: ...s released PJ Lock status is OFF or status is ON 1 or ON 2 on Menu but PJ PIN CODE is entered correctly so that PJ Lock is released Unacceptable Error Code CR 9 11 21 CR_PJLOCKMENU Command Command CR_PJLOCKMENU CR Details Get status of PJ Lock on Menu Response Acceptable 000_ 1 CR 1 ON1 PJ Lock status is On 1 ON2 PJ Lock status is On 2 OFF PJ Lock status is OFF Unacceptable Error Code CR 9 11 22CR...

Страница 64: ...LREPL Command Command CR_FILREPL CR Details Get the information of Filter replacement time Response Acceptable 000_ 1 CR 1 1Y Over filter replacement time 1N Within filter replacement time Unacceptable Error Code CR 9 11 26CR_FILTIMER Command Command CR_FILTIMER CR Details Get setting time which filter warning OSD is displayed Response Acceptable 000_ 1 CR 1 100 100 hours 200 200 hours 300 300 hou...

Страница 65: ... 21 Cooling down due to Lamp failure 81 Stand by after Cooling down due to Lamp failure Unacceptable Error Code CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get Signal status if there is signal or not Response Acceptable 000_ a CR a ON Signal is found OFF There is no signal Unacceptable Error Code CR 9 12 3 CR_VMUTE Command Command CR_VMUTE CR Details Get setting status of No Show Resp...

Страница 66: ...e Acceptable 000_ a_ b_ c CR a b c a Sensor 1 status b Sensor 2 status c Sensor 3 status W Approach or reach abnormal temperature dangerous temperature S Far from abnormal temperature safe temperature N Sensor detects no abnormal temperature Example S_W_S CR means Sensor 1 detects safe temperature Sensor 2 detects abnormal temperature and Sensor 3 detects safe temperature Note When the temperature...

Страница 67: ...high to display Warning S Not close to abnormal temperature Temperature is low enough and safe N Applicable sensor does not detect abnormal temperature E Not able to return temperature data When several sensors are incorporated projector returns values continuously e g _31 5F__35 2S__38 0W CR A data of sensor 1 comes first and a data of sensor 2 follows after 1 space As described respectively in e...

Страница 68: ... 5F CR _ indicates a space When the temperature sinks to the first character is like 05 5F CR The last character means the sensor s status if it reaches abnormal temperature Exceeding critical temp F Temp is safe S Sensor detects no critical temp N The example shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal When the temperature is safe all data are represented as 000S Wh...

Отзывы: