PLC-XU305A/355A Expand Serial Command Functional Specifications
46/68
9.4.11 CR_NZRED Command
Command “CR_NZRED”[CR]
Details
Get setting status of Noise Reduction
Response
Acceptable
“000_%1”[CR]
%1
“L1” -------- Noise Reduction for moving image
“L2” -------- Noise Reduction for still image
“OFF” ----- Noise Reduction is OFF
Unacceptable “Error Code”[CR]
9.4.12 CR_PROGV Command
Command “CR_PROGV”[CR]
Details
Get setting status of Progressive scan
Response
Acceptable
“000_%a”[CR]
%a
“L1” ----------------- Progressive Mode L1 is selected
“L2” ----------------- Progressive Mode L2 is selected
“FILM” -------------- Progressive Model FILM is selected
“OFF” --------------- Progressive scan is disabled
Unacceptable “Error Code”[CR]
9.4.13 CR_IMAGE Command
Command “CR_IMAGE”[CR]
Details
Get image setting status
Required data “CUSTOM1” to “CUSTOM4” is the same as “Image1” to “Image4”
displayed when selecting IMAGE on OSD menu
Response
Acceptable
“000_%a”[CR]
%a
“DYNAMIC” --------------------------------------- Dynamic
“STAND” ------------------------------------------- Standard
“REAL” --------------------------------------------- Real
“CINEMA” ----------------------------------------- Cinema
“BLACKBOARD” -------------------------------- Blackboard
“COLORBOARD” -------------------------------- Colorboard
“CUSTOM1”~”CUSTOM4” -------------------- Image1~4
Unacceptable
“Error Code”[CR] ---- When the command is invalid due to
condition such as Input source
“?”[CR] -------------------- When unclear command is received
9.4.14 CR_IMGGMD Command
Command "CR_IMGGMD”[CR]
Details
Get Image Gamma setting status
Response
Acceptable
“000_%a”[CR]
%a
“DYN” ------------ Dynamic
“STD” ------------ Standard
“REL” ------------ Real
“CNM” ----------- Cinema
“BKB” ------------ Blackboard
“CLB” ------------ Colorboard
Unacceptable “Error Code”[CR]