-41-
9. Contrast adjustments-AV
Equipment
Oscilloscope.
Input mode
AV.
Input signal
16 step gray scale signal
Set the image to "Service mode."
Adjust each test point value part-A in a figure minimum amplitude with the Volume
+ and - buttons.
Group No.
Connection
210-
8
TP2526 (Green contrast adjustment)
210-
9
TP2536 (Red contrast adjustment)
210-
10
TP2516 (Blue contrast adjustment)
A
Black Level
Pedestal
Level
10. Panel driving signal adjustments -AV
Equipment
Oscilloscope.
Input mode
AV.
Input signal
16 step gray scale signal
Picture condition
Normal.
Set the image to "Service mode."
Adjust each item for below values with the and - buttons.
Group No.
Connection
Adjustment
part.
Adjustment or adjustment value.
210-
11
TP2526(Green)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
210-
12
TP2526(Green)
Amplitude-B in a figure.
1.6 ± 0.05Vp-p
210-
13
TP2536(Red)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
210-
14
TP2536(Red)
Amplitude-B in a figure.
1.6 ± 0.05Vp-p
210-
15
TP2516(Blue)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
210-
16
TP2516(Blue)
Amplitude-B in a figure.
1.6 ± 0.05Vp-p
11. Panel driving signal adjustments -PC
Equipment
Oscilloscope.
Input mode
Computer
Input signal
16 step gray scale signal
Set the image to "Service mode."
Adjust each item for below values with the and - buttons.
Group No.
Connection
Adjustment
part.
Adjustment or adjustment value.
200-
11
TP2526(Green)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
200-
12
TP2526(Green)
Amplitude-B in a figure.
1.5 ± 0.05Vp-p
200-
13
TP2536(Red)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
200-
14
TP2536(Red)
Amplitude-B in a figure.
1.5 ± 0.05Vp-p
200-
15
TP2516(Blue)
Amplitude-A in a figure.
4.0 ± 0.05Vp-p
200-
16
TP2516(Blue)
Amplitude-B in a figure.
1.5 ± 0.05Vp-p