-45-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
6 Not used
-
Group
253
Fan tem error Setting (Memorized)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 Temp A Warning (High)
44
44
41
41
-
1 Temp B Warning (High)
54
54
54
54
-
Temp C Warning (High)
60
60
58
58
-
Temp B-A Warning(High)
100
100
100
100
-
4 Temp C-A Warning(High)
100
100
100
100
-
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
4
4
41
41
0-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
54
54
5
5
0-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
58
58
57
57
0-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at Eco
(Room)
4
4
41
40
0-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
54
54
5
5
0-100
1 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
57
56
55
55
0-100
1 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
5
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
0 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
0-100
1 Temp B Warning Offset
(Time)
0-100
Temp C Warning Offset
(Time)
0-100
Temp B-A Warning Offset
(Time)
0-100
4 Temp C-A Warning Offset
(Time)
0-100
Group
254
Fan control range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
1
-
1 High Fan Control Max Temp
41
41
8
8
-
High Fan1 Min
78
80
95
100
-
High Fan1 Max
15
15
15
15
-
4 High Fan Min
67
75
85
95
-
5 High Fan Max
90
95
110
115
-
6 High Fan Min
75
80
100
105
-
7 High Fan Max
15
15
15
15
-
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
0-100
11 Normal Fan Control Max
Temp
40
40
8
8
0-100
1 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
68
75
96
100
0-55
1 Normal Fan1 Max
15
15
15
15
0-55
14 Normal Fan Min
7
77
114
10
0-55
15 Normal Fan Max
108
11
150
155
0-55
16 Normal Fan Min
70
75
100
105
0-55
17 Normal Fan Max
15
15
15
15
0-55
0 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
1
0-100
1 Eco Fan Control Max Temp
40
40
8
7
0-100
Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
5
60
75
80
0-55
Eco Fan1 Max
10
10
15
15
0-55
4 Eco Fan Min
50
55
60
65
0-55
5 Eco Fan Max
65
70
75
80
0-55
6 Eco Fan Min
55
60
75
75
0-55
Содержание PLC-XE33
Страница 19: ... 19 Optical Parts Disassembly b Relay Out lens disassembly Relay Out lens Relay lens Ass y Fig 5 M 2 5x6 ...
Страница 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 LC87F2G08A5AN6 UART IC9885 ...
Страница 66: ... 66 IC Block Diagrams MAX232ECPWRP RS 232C Driver IC3801 L3E06170 D A S H LCD Driver IC501 IC531 IC561 ...
Страница 68: ... 68 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631 ...
Страница 69: ... 69 IC Block Diagrams PIC18F67J60 LAN CONTROL IC8801 FA7703 DC DC Converter IC7811 ...
Страница 93: ...KD8 XE3300 93 Mechanical Parts List ...
Страница 94: ... KD8AC August 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Страница 104: ...A10 SCH_KR5AC NO DATA ...
Страница 108: ...A14 PCB_KR5AC NO DATA ...