-3-
Safety Instructions
WARNING:
The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side
of the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is
identified with the line (
) in the schematic diagram. For continued product safety and protection of per-
sonnel injury, servicing should be made with qualified personnel.
The following precautions must be observed.
Safety Precautions
1: An isolation transformer should be connected in
the power line between the projector and the AC line
before any service is performed on the projector.
: Comply with all caution and safety-related notes
provided on the cabinet back, cabinet bottom, inside
the cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always
be certain that all the protective devices are
installed properly, such as, control knobs, adjust-
ment covers or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND PR
OPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray
parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe
to operate without danger of electric shock.
Service Personnel Warning
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always
turn off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages (15kV - 5kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
Product Safety Notice
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
!
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there
parts must be made by exactly the same parts.
do Not AttEMPt to SERVICING tHE REMotE CoNtRoL UNIt.
Laser Beam may be leaked out when in disassemble the Unit. As the Laser Beam
used in this Remote control unit is harmful to the eyes.
If the Remote Control unit is failed, please replace it with a new one.
Battery Replacement Notice
Caution
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the manufacture’s instructions.
Replace Battery With SANYO Electric Co., Ltd., Part No. 645 089 8587 Only. Use of Another Battery May
Present A Risk Of Fire or Explosion.
Содержание PLC-WXU30A
Страница 69: ... 69 IC Block Diagrams FA7701 DDC Control IC5751 AN5870 Signal Switch IC5201 ...
Страница 70: ... 70 IC Block Diagrams FA7711 DC DC Converter IC5801 FA5550N P F Control IC621 ...
Страница 71: ... 71 IC Block Diagrams L3E06150 D A S H LCD Driver IC501 IC531 IC561 SP3232ECYP RS 232C Driver IC3801 ...
Страница 72: ... 72 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 L3E07111 LCD Driver Gamma Correction IC401 ...
Страница 73: ... 73 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001 ...
Страница 74: ... 74 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631 ...
Страница 75: ... 75 IC Block Diagrams TE7783 Parallel I O Expander IC1802 ...
Страница 111: ...KB3 WXU30A00 111 Mechanical Parts List 527 528 L14 L10 L03 L15 L07 L16 L13 L09 L06 L08 In the Optical Unit L11 L14 ...
Страница 113: ...KB3 WXU30A00 113 Mechanical Parts List ...
Страница 114: ... KB3AE November 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Страница 132: ...A18 PCB_KB3AE ...