PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
84/88
9.11.40 CR_SHUTH Command
Command
“CR_SHUTH” [CR]
Details
Get time setting to start the shutter management
Acceptable
“000_%1” [CR]
%1
“005” --------------------
5 minutes
“006” -------------------- 6
minutes
:
“479” -------------------- 479
minutes
“480” -------------------- 480
minutes
Response
Unacceptable
“Error Code” [CR]
9.11.41 CR_CCAPTIONDISP Command
Command
“CR_CCAPTIONDISP”[CR]
Details
Get selected channel of Closed caption
Acceptable
“000_%a”[CR]
%
a
“OFF” --------- Off
“CC1” --------- CC1 is selected
“CC2” --------- CC2 is selected
“CC3” --------- CC3 is selected
“CC4” --------- CC4 is selected
Response
Unacceptable
“Error Code”[CR]
9.11.42 CR_CCAPTIONCOLOR Command
Command
“CR_CCAPTIONCOLOR”[CR]
Details
Get selected color of Closed caption
Acceptable
“000”[CR]
%a
“COLOR” ------- Color is selected
“WHITE” -------- White is selected
Response
Unacceptable “Error Code”[CR]
9.11.43 CR_DELAYCTRL Command
Command
“CR_DELAYCTRL” [CR]
Details
Get setting status of Video delay control
Acceptable
“000_%1” [CR]
%1
“OFF”---------- Set Video delay control to OFF
“LOW”---------- Set Video delay control to LOW
“MID”---------- Set Video delay control to MID
“HIGH”---------- Set Video delay control to HIGH
Response
Unacceptable ““Error Code” [CR]