
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
64/88
9.7 Input Read Command
9.7.1
CR_INPUT Command
Command
“CR_INPUT” [CR]
Details
Get selected INPUT No.
Acceptable
“000_%1” [CR]
%1
“1 – 4”
Response
Unacceptable
“Error Code” [CR]
9.7.2
CR_SOURCE Command
Command “CR_SOURCE” [CR]
Details
Get selected source
Acceptable
“000_%1” [CR]
%1
“ANALOG” -------------- RGB (PC Analog) is selected
“SCART” ----------------- RGB (Scart) is selected
“HDMI” --------------------HDMI is selected
“VIDEO” ------------------ Video is selected
“S-VIDEO” --------------- S-Video is selected
“YPBPR” ----------------- Y,Pb/Cb,Pr/Cr is selected
“NETWORK” ------------ Network is selected
Response
Unacceptable
“Error Code” [CR] --- When command is not available in the given
condition (such as being selected input)
“?” [CR] ---------------- When unknown command is received
9.7.3
CR_SRCINP1 Command
Command “CR_SRCINP1” [CR]
Details
Get Source of INPUT1
Acceptable
“000_%1” [CR]
%1
“ANALOG” ---------------------- in PC Analog mode
“SCART” ------------------------ in Scart mode
“HDMI” --------------------------- in HDMI mode
Response
Unacceptable
“Error Code” [CR]
9.7.4
CR_SRCINP2 Command
Command “CR_SRCINP2” [CR]
Details
Get Source of INPUT2
Acceptable
“000_%1” [CR]
%1
“VIDEO” --------------------- in Video mode
“YPBPR” -------------------- in Y,Pb/Cb,Pr/Cr mode
“ANALOG” ------------------ in RGB mode
Response
Unacceptable
“Error Code” [CR]