PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
41/88
8.10.4 CF_DISP Command
Command
“CF_DISP_%1” [CR]
%1
“ON” ----------------------------- Set Display to On
“CNTDWNOFF” --------------- Set Display to Count down Off
“OFF” --------------------------- Set Display to Off
“UP” --------------- Switch forward (On
→
Count down Off
→
Off
→
On
→
---)
“DN” --------------- Switch backward (On
→
Off
→
Count down Off
→
On
→
---)
Details
Set Display mode.(Available only in the normal Power ON status)
The value set by this command is stored in EEPROM and setting remains effective
even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.10.5 CF_BACKGND Command
Command “CF_BACKGND_%1” [CR]
%1
“BLUE” -------------------- Select Blue Back
“USER” ------------------- Select User
“BLACK” ------------------ Select Black Back
“UP” ---------- Switch forward (Blue Back
→
User
→
Black Back
→
Blue Back)
“DN” --------- Switch backward (Blue Back
→
Black Back
→
User
→
Blue Back)
Details
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
*When
%
1=”USER” is received, error code “101” is returned, in the case of
Capture non-practice.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]