-8-
■
Flat Cable Removal
This set is used 3 kinds of connector for flat cable. For removal of cable, refer as below not to damage.
■
For Gasket
The gasket is provided to prevent exposure of interference for other radio and television receptions.
The gasket should be
replaced on previous positions
after servicing.
For removal of flat cable, slide hook of
both sides.
For insert and fixing, slide hook to pre-
vious position after inserting the flat
cable.
Type A
Type B
Type C
For removal of flat cable, lift up hook of
both sides.
For insert and fixing, hold down hook
after inserting the flat cable.
For removal of flat cable, pull off only.
For fixing , insert into socket.
Cable
Cable
Cable
Mechanical Disassemblies
■
Notice for service of Board
In below boards, can be repaired inside parts or unit itself. Order service parts for repair.
Main
Power
Jack-A
Jack-B
Sensor-A
Sensor-B
Control
Note:
Control Board and Membrane Switch are fixed at Cabinet Front.