PDG-DXL2000 Expand Serial Command Functional Specifications
60/72
9.9.5 CR_LAMPMSTS Command
Command “CR_LAMPSTS”[CR]
Details
Get Lighting status of lamp
Acceptable
“000_%1”[CR]
%1
“
n
**** ” A number of * should be among 1-4.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Second character shows following status in order of lamp number.
“I” Lamp is ON
“O” Lamp is OFF
“X” Lamp failure
e.g.
“1I”
・・・・・・・
1 Iamp model and Lamp is ON
“2IO
・・・・・・・
2 lamps model and No.1 Lamp is ON and No.2Lamp
is OFF
“4IOXI”
・・・・
4 lamps model and No.1,No.4 lamps are ON. No.2
lamp is OFF and No.3 model is failed.
Response
Unacceptable “Error Code”[CR]
9.9.6 CR_PROJH Command
Command “CR_PROJH”[CR]
Details
Get total running time of Projector by hour (h)
Acceptable
“000_%1”[CR]
%1
“0000000”~“0099999”
Response
Unacceptable “Error code”[CR]
9.9.7 CR_HMLAMP Command
Command “CR_HMLAMP”[CR]
Details
Get lamp number.
Acceptable
“000_%1”[CR]
%1
“001”
Response
Unacceptable “Error Code” [CR]