PDG-DHT8000L Expand Serial Command Functional Specifications
95/101
9.11
Other Status Read Commands
9.11.1 CR_STATUS Command
Command “CR_STATUS” [CR]
Details
Get operating status of Projector
Same as “CR0” in basic command except error code follows it.
Acceptable
“000_%1” [CR]
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal temperature
“88” =Standby after Cooling Down due to abnormal temperature
“02” = Invalid RS-232C Command
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turned off due to lamp failure
“81”
=
Standby after Cooling Down due to lamp failure
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C” = Standby after Cooling Down due to Shutter management
Response
Unacceptable “Error Code” [CR]
9.11.2 CR_SIGNAL Command
Command “CR_SIGNAL” [CR]
Details
Get status if there is any signal or not
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- There is signal
“OFF” ------------------------ There is no signal
Response
Unacceptable “?” [CR]
9.11.3 CR_VMUTE Command
Command “CR_VMUTE” [CR]
Details
Get Video mute setting status
Acceptable
“000_%1” [CR]
%1
“ON” ------------------------ Video mute is set to ON (Shutter Close).
“OFF” ---------------------- Video mute is set to OFF (Shutter Open).
Response
Unacceptable “?” [CR]
9.11.4 CR_FREEZE Command
Command
“CR_FREEZE” [CR]
Details
Get Freeze setting status
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------------- Freeze is set to ON.
“OFF” -------------------------- Freeze is set to OFF.
Response
Unacceptable
“?” [CR]