![background image](http://html.mh-extra.com/html/sanyo/pdg-dht8000l-8000-lumens/pdg-dht8000l-8000-lumens_specifications_362120080.webp)
PDG-DHT8000L Expand Serial Command Functional Specifications
80/101
9.9.9 CR_LAMPCORRESPH Command
Command “CR_LAMPCORRESPH” [CR]
Details
Get Lamp running time (in hours)
*return lamp running time multiplied by a coefficient (not actual running time)
Acceptable
“000_%1” [CR]
%1
“00000”-“99999”
Response
Unacceptable “Error Code” [CR]
9.9.10 CR_LAMPINTERVAL Command
Command “CR_LAMPINTERVAL” [CR]
Details
Get setting status of Lamp interval
Acceptable
“000_%1” [CR]
%1
“AUTO” ---------------- Auto is selected
“0024”------------------ 24 Hours is selected
“0200”------------------ 200 Hours is selected
“0500”------------------ 500 Hours is selected
“1000”------------------ 1000 Hours is selected
“2000”------------------ 2000 Hours is selected
“OFF” ------------------ Off is selected
Response
Unacceptable “?” [CR]
9.9.11 CR_LAMPLIFECONTRL Command
Command “CR_LAMPLIFECONTRL” [CR]
Details
Get setting status of Lamp life control.
(Available only in the normal Power ON status)
Acceptable
“000_%1” [CR]
%1
“MODE1” ---------------- Mode1 is selected
“MODE2”----------------- Mode2 is selected
Response
Unacceptable “Error Code” [CR]