-5-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
1
Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
-
255
2
Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
241
Flow Ideal Data
(Value will be set after calibration)
0
Flow Ideal Data 1
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
0 - 1023
377
1
Flow Ideal Data 2
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
0 - 1023
486
2
Flow Ideal Data 3
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
0 - 1023
513
3
Flow Ideal Data 4
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
0 - 1023
538
4
Flow Ideal Data 5
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
0 - 1023
563
5
Flow Ideal Data 6
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
0 - 1023
1023
6
Flow Ideal Data 7
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
0 - 1023
1023
7
Flow Ideal Data 8
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
0 - 1023
1023
242
Flow Calib. Fan Volt
(Not Memorized)
0
Flow Calib Fan Volt 1
Flow Sensor Calibration Fan Volt No.1 [V x10]
0 - 255
65
1
Flow Calib Fan Volt 2
Flow Sensor Calibration Fan Volt No.2 [V x10]
0 - 255
95
2
Flow Calib Fan Volt 3
Flow Sensor Calibration Fan Volt No.3 [V x10]
0 - 255
110
3
Flow Calib Fan Volt 4
Flow Sensor Calibration Fan Volt No.4 [V x10]
0 - 255
125
4
Flow Calib Fan Volt 5
Flow Sensor Calibration Fan Volt No.5 [V x10]
0 - 255
138
5
Flow Calib Fan Volt 6
Flow Sensor Calibration Fan Volt No.6 [V x10]
0 - 255
255
6
Flow Calib Fan Volt 7
Flow Sensor Calibration Fan Volt No.7 [V x10]
0 - 255
255
7
Flow Calib Fan Volt 8
Flow Sensor Calibration Fan Volt No.8 [V x10]
0 - 255
255
243
Flow Calib Effective Difference
(Not Memorized)
0
Flow Calib Effective Diff 1
Flow Sensor Calibration Range Diff No.1 [ADC]
0 - 1023
250
1
Flow Calib Effective Diff 2
Flow Sensor Calibration Range Diff No.2 [ADC]
0 - 1023
250
2
Flow Calib Effective Diff 3
Flow Sensor Calibration Range Diff No.3 [ADC]
0 - 1023
250
3
Flow Calib Effective Diff 4
Flow Sensor Calibration Range Diff No.4 [ADC]
0 - 1023
250
4
Flow Calib Effective Diff 5
Flow Sensor Calibration Range Diff No.5 [ADC]
0 - 1023
250
5
Flow Calib Effective Diff 6
Flow Sensor Calibration Range Diff No.6 [ADC]
0 - 1023
1023
6
Flow Calib Effective Diff 7
Flow Sensor Calibration Range Diff No.7 [ADC]
0 - 1023
1023
7
Flow Calib Effective Diff 8
Flow Sensor Calibration Range Diff No.8 [ADC]
0 - 1023
1023
244
Flow Clog Threshold
(Not Memorized )
0
Flow Clog Threshold 1
Flow Sensor Clogged Threshold No.1[ADC]
0 - 1023
48
1
Flow Clog Threshold 2
Flow Sensor Clogged Threshold No.2[ADC]
0 - 1023
47
2
Flow Clog Threshold 3
Flow Sensor Clogged Threshold No.3[ADC]
0 - 1023
48
3
Flow Clog Threshold 4
Flow Sensor Clogged Threshold No.4[ADC]
0 - 1023
52
4
Flow Clog Threshold 5
Flow Sensor Clogged Threshold No.5[ADC]
0 - 1023
58
5
Flow Clog Threshold 6
Flow Sensor Clogged Threshold No.6[ADC]
0 - 1023
1023
6
Flow Clog Threshold 7
Flow Sensor Clogged Threshold No.7[ADC]
0 - 1023
1023
7
Flow Clog Threshold 8
Flow Sensor Clogged Threshold No.8[ADC]
0 - 1023
1023
245
Filter Roll
0
Take Up Bend
Remove Filter Flexure Starts when the Value is set to 1.
0 - 1
0
1
Take Up Times
Remaining Times of Filter Scroll (Read only)
-
-
2
Take Up Time Reset
Filter Scroll Times Reset
Resets Remaining Scroll Times when the Value is set to 10.
0 - 10
0
3
Scroll Counter Reset Time
Scroll Counter Reset Times (Read only)
0 - 255
-
4
Scroll Information Cartridge No
0 - 2
0
246
Flow Clog Monitor
(Read only)
0
Real Flow Data
Real Flow Data [ADC] (Read only)
0 - 1023
-
1
Ideal Flow Data
Theory Flow Data (Read only)
0 - 1023
-
2
Flow Difference Data
Flow Difference Data [ADC] (Read only)
-1023 - 1023
-
3
Clog Detect Flow Difference Data Difference Data to judge the Filter Clogged [ADC] (Read only)
0 - 1023
-
4
Warn Detect Flow Difference Data Difference Data to judge the Filter Clogged Warning [ADC] (Read
only)
0 - 1023
-
5
Press Add Data
Add Data by Air Pressure (Read only)
0 - 1023
-
6
Filter Scroll Timer
Timer for Filter Scroll [hour] (Read only)
0 - 32767
-
247
Filter Scroll Time
(Read only)
0
Filter 1st Cartridge Scroll Time 1
1st Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767
9999
1
Filter 1st Cartridge Scroll Time 2
0 - 32767
9999
Содержание PDG-DET100L - SXGA+ DLP Projector
Страница 45: ... 45 Electrical Adjustment Test Points and Locations K66S 1 7 ...
Страница 148: ... 148 IC Block Diagrams AD8185ARUZ Slot RGB SW IC9031 THS7347IPHPR Analog SW IC1201 ...
Страница 149: ... 149 IC Block Diagrams CXA2239AR Componemt SW IC2201 ISL51002CQZ A D IC201 ...
Страница 150: ... 150 IC Block Diagrams BA7078AF Sync Sep IC5321 M62393FP DAC IC7801 ...
Страница 151: ... 151 IC Block Diagrams EDD2516AETA RAM IC1311 IC1331 TE7783APF I O Expander IC1801 ...
Страница 152: ... 152 IC Block Diagrams K4S641632K SDRAM IC3401 PW392 Scaler IC301 ...
Страница 153: ... 153 IC Block Diagrams NJM2671 Motor Drive IC5581 PW610 Keystone IC2301 ...
Страница 154: ... 154 IC Block Diagrams THC63LVD1023B LVDS Transmitter IC7201 THC63LVD1024 LVDS Receiver IC7601 ...
Страница 155: ... 155 IC Block Diagrams 2506502 DLP Data Processor IC401 IC1401 2506224 Power Motor Drive IC2501 IC2551 ...
Страница 156: ... 156 IC Block Diagrams MT49H8M36BM RL DRAM IC501 2503253 DMD Driver IC3501 ...
Страница 208: ... KJ5AL Jun 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Страница 222: ...A14 SCH_KJ5AL 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA ...