background image

SPECIFICATIONS

Mechanical Loading

The modules should be mounted at 

the 4 or more points as shown in Fig1-1 

,

Fig1-2 , Fig2-1 , Fig2-2 . Then, a maximum 

loading of  2400N/m

2

(50PSF,  in 

static    state) on the module surface 

is possible.

CERTIFICATION

The HIP-xxxNHE5, xxxNHE5-BO2, 

HIP-xxxBE11, -xxxBE11-BO2

Modules comply with the 

requirements of IEC61215, Electrical 

protection Class II and the CE mark.

Electrical Specifications

(HIP-215NHE5, -215NHE5-BO2, -210NHE5, -210NHE5-BO2, -205NHE5, -205NHE5-BO2, -200NHE5, 

-200NHE5-BO2, -195NHE5, -195NHE5-BO2)

*HIT= Hetero junction with Intrinsic Thin-layer

Note: The values in the above table are nominal.

WIRING

General

All wiring should be done in accordance with applicable electrical codes. 

All wiring should be done by the qualified licensed professional.

Wiring should be protected to help ensure personal safety and to prevent its damage.

All modules connected in series should be of the same model number/type.

Do not connect modules in parallel without using a connection box.

3

Printed in Europe 20.10.2006

Metal fitting

Spring washer

Flat washer

Module

Mounting Structure Rail

M6 Bolt/setscrew

M6 Nut

Metal fitting

(4 places)

Mounting
Structure Rail

Between Modules

Mounting Structure Rail

Solar Module

Metal fitting

End of Module

φ 

Installation (reference) – HIP-xxxBE11, -xxxBE11-BO2

Figure1-2 : Installation

Notes on specification

(1) Powered specifications are 

measured at Standard Test Condition 

Irradiance of : 1000W/m

2

, 25

o

C cell 

temperature and solar spectral irradiance 

per IEC 60904-3.

(2) The current output for these modules 

as shown in the Specifications is 

measured at Standard test conditions. 

These conditions may not be frequently 

observed in actual practice.

For questions regarding mounting profiles for modules, please contact your local dealer.

Содержание HIP-215NHE5

Страница 1: ...s and burns are still a potential hazard To avoid the hazard of electric shock and injury cover all over the front surface of PV modules with a dense opaque material such as the cardboard box during installing and handling modules The shock hazard increases as modules are connected in parallel producing higher current The shock hazard increases as modules are connected in series producing higher v...

Страница 2: ...les please contact your local dealer GENERAL SAFETY Follow all permission installation and inspection requirements Before installing module contact appropriate authorities to determine permission installation and inspection requirements that should be followed This should be done not only for installations in conjunction with buildings but also for marine and motor vehicle applications for which a...

Страница 3: ... protected to help ensure personal safety and to prevent its damage All modules connected in series should be of the same model number type Do not connect modules in parallel without using a connection box 3 Printed in Europe 20 10 2006 Metal fitting Spring washer Flat washer Module Mounting Structure Rail M6 Bolt setscrew M6 Nut Metal fitting 4 places Mounting Structure Rail Between Modules Mount...

Страница 4: ... to follow the safety recommendations of their manufactures These modules contain factory installed bypass diodes If these modules are incorrectly connected to each other the bypass diodes or cable or junction box may be damaged Array Wiring The term array is used to describe the assembly of several modules on a support structure with associated wiring Use copper wire that is sunlight resistant an...

Страница 5: ...or the systems within the specified system voltage so that you don t need any other additional bypass diodes Contact your authorized SANYO distributor or dealer for proper diode type if necessary to add or change diodes due to system specification MAINTENANCE Some maintenance is recommended to maintain optimal output performance of solar cell modules If the module surface becomes dirty it may caus...

Страница 6: ... Corporation TEL 82 2 777 6468 FAX 82 2 777 5997 SANYO Energy Taiwan Co Ltd TEL 886 2 8780 8810 FAX 886 2 8780 8850 SANYO Thailand Co Ltd TEL 66 2 248 3491 FAX 66 2 246 7250 SANYO Sales Marketing Corporation TEL 81 6 6992 1482 FAX 81 6 6992 1553 Africa SANYO South Africa Pty Ltd TEL 27 11 448 2929 FAX 27 11 448 2860 Middle East SANYO Gulf Fze TEL 971 4 8873939 FAX 971 4 8873969 The return of any m...

Отзывы: