background image

4

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

5

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

ECO G 3 Way Outdoor Unit Specifications

ECO G 3 Way Heat Recovery VRF System

LPG option

The option of using LPG as a power supply increases flexibility 

and  avoids  the  problems  of  potential  site  restrictions  in  the 
future.  The  purer  fuel  is  also  excellent  for  further  reductions 
in CO

2

 emissions - a fact recognised by the government.

Still the only heat recovery (3 way) GHP system in 

Europe. 

The  new  M  Series  ECO  G  3  Way  offers  even  more 

performance  and  outstanding  features  when  you  need 

simultaneous  heating  and  cooling.  Now  with  increased 

capacities available from 16HP to 25HP, SANYO offers the 

greatest choice and flexibility to solve any power problem or  

site requirement.

• Simultaneous heating and cooling for total control

• Reduced gas consumption by Miller-cycle engine

•  Reduced electrical power consumption by using DC motors

•  New  lightweight  design  by  use  of  aluminium  engine  block 

reduces weight by 110kg

• Part load efficiencies increased

• Connectability increased to up to 36 indoor units

• Now available in 16, 20 and 25HP

• 200m maximum allowable piping length (L1) (equivalent - refer 

to technical manual)

• Diversity ratio 50% - 130%

• Extended pipe runs (total 500m)

• Silent mode offers a further 2dB(A) reduction

•  10,000 run hours between engine service intervals (equivalent 

to one maintenance every 3.2 years*)

• Full heating capacity down to -20°C

• No defrost cycle

* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks

ECO G 3 Way is ideal for the following types of 

application:

•  Office  buildings  with  a  diverse  range  of  room  temperatures 

due to differing load profiles.

•  Buildings with computer rooms requiring year round cooling.

Additional parts

By  taking  its  power  supply  from  the  nearest  indoor  unit,  the 
SANYO solenoid valve (change-over box) does not require any 
additional  fused  spur  and  at  only  150mm  high  can  be  easily 
installed within a 200mm void space.

Dimensions ECO G 3 Way (16-25HP)

Comparison of the start times for heating operation

Room temperature (˚C )

Gas heat pump

Electric heat pump

Time axis (in case of the same load)

Outside air temperature (˚C)

Electric heat pump

Gas heat pump

Comparison of heating capacity

Heating capacity (% )

Comparison of the start times for heating operation

Room temperature (˚C )

Gas heat pump

Electric heat pump

Time axis (in case of the same load)

Outside air temperature (˚C)

Electric heat pump

Gas heat pump

Comparison of heating capacity

Heating capacity (% )

HP

16

20

25

Model

SGP-EZ150M2G2

SGP-EZ190M2G2

SGP-EZ240M2G2

Capacity

Cooling

kW

45.0

56.0

71.0

Heating 

STD

kW

50.0

63.0

80.0

Heating  Low temp*

53.0

67.0

75.0

Electricity

Cooling

kW

1.35

Heating

kW

1.01

1.54

Gas 

Cooling

kW

31.6

38.3

60.9

Heating 

STD

kW

36.1

43.0

58.0

Heating 

LOW

47.3

56.4

64.9

COP

Cooling

1.37

1.41

1.14

Heating

1.35

1.43

1.34

AVE

1.36

1.42

1.24

Size

Height

mm

2,248

Width

1,800

Depth

1,000 (+60)

Weight

kg

845

875

Starter amperes

A

30

Piping 

connection

Gas

Inches (mm)

1 1/8 (28.58)

Discharge

7/8 (22.22)

Liquid

3/4 (19.05)

Pipe fuel gas

R3/4 (bolt thread)

Pipe exhaust drain

mm

ø 25 rubber hose

Operation sound

dB(A)

57

58

62

Indoor/outdoor capacity ratio

50-180% *1

Number of indoor connections

36

* 1: Low temp condition: Outdoor temperature 2 C˚.

 

Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. 

Please refer to tube sizing charts for pipe selections and pipe length parameters.

Rear View

Front View

Left Side View

at least 2000

Service Clearances for installation

(Units: mm)

Rear

(refrigerant tubing)

Rear

(refrigerant tubing)

at

 le

as

60

0

at

 le

as

60

0

at

 le

as

10

00

at

 le

as

10

00

at least 

100

at least 

100

at least 

100

at least 

350

at least 

350

Front View

Front View

(Single-unit installation)

(Multi-unit series installation)

Suction refrigerant pipe

ø28.58

ø22.22

Size (mm)

Model Type

150

190   240

ø25.4

ø19.05

ø28

ø28

G: R3/4

ø20

4 - ø20

4 - ø24

OD: ø25 Length: 200

1

Discharge refrigerant pipe

2

Liquid refrigerant pipe

3

Exhaust gas drain hose

4

Inter-unit cable port

5

Electrical power supply port

6

Fuel gas port

7

Condensation drain opening

8

Rain and condensation outlet

9

Engine exhaust outlet

10

Suspension holes

11

Anchor holes

12

Segmented display

13

Coolant intake (top)

14

Vent

15

Top View

1800 (external)

22

48

 (+

30

)

(1

81

)

400

10

14

(a

nc

ho

r p

itc

h)

1000

(anchor pitch)

10

14

12

13

1030 (suspension holes)

1000 (external)

ø736

1060 (frame width)

9

15

11

27

54

147

22

99

10

8

18

1

57

207

242

279

312

55

5

271

7

6

5

4

3
1
2

8

Содержание ECO G SGP-EGW190M2G2W

Страница 1: ...SANYO Air Conditioners The natural choice Gas Driven VRF M Series GAS DRIVEN VRF ELECTRIC VRF COMMERCIAL SPLIT SYSTEMS ROOM AIR CONDITIONERS HEATING SOLUTIONS ...

Страница 2: ... supply problems If you are short of electrical power gas heat pump could be the perfect solution Runs on gas and just needs single phase supply Enables the building s electrical power supply to be used for other critical electrical demands Reduces capital cost to upgrade power substations to run heating and cooling systems Reduces power loadings within a building especially during peak periods El...

Страница 3: ...re C Gas heat pump Electric heat pump Time axis in case of the same load Outside air temperature C Electric heat pump Gas heat pump Comparison of heating capacity Heating capacity Comparison of the start times for heating operation Room temperature C Gas heat pump Electric heat pump Time axis in case of the same load Outside air temperature C Electric heat pump Gas heat pump Comparison of heating ...

Страница 4: ...onsumption Cooling kW 24 50 31 60 38 30 60 90 49 00 56 10 63 20 62 80 69 90 76 60 99 20 121 80 Heating STD kW 28 10 36 10 43 00 58 00 56 20 64 20 72 20 71 10 79 10 86 00 101 00 116 00 Heating LOW 36 80 47 30 56 40 64 90 73 60 84 10 94 60 93 20 103 70 112 80 121 30 129 80 COP Cooling 1 40 1 37 1 41 1 14 1 40 1 38 1 37 1 41 1 39 1 41 1 25 1 14 Heating 1 37 1 35 1 43 1 34 1 37 1 36 1 35 1 41 1 39 1 4...

Страница 5: ... STD kW 48 7 43 0 76 80 84 80 97 40 101 00 Heating LOW 62 1 56 4 98 90 109 40 124 20 121 30 COP Air conditioning only Cooling 1 33 1 41 1 29 1 23 1 18 Heating 1 34 1 43 1 31 1 30 1 27 1 38 AVE 1 34 1 42 1 30 1 25 1 28 Max COP Inc generater hot water Cooling 1 78 1 81 1 80 1 78 1 69 Height Height mm 2 248 Width 1 800 1 800 100 Min distance 1 800 Depth 1 000 60 Weight kg 875 1 660 1 685 1 740 1 720 ...

Страница 6: ... 59 Nominal air flow Sound pressure 1 5 mts from the unit in free field Data referred to 50 C 80 RH OAT room condition 200 C 50 RH Data referred to 320 C 50 RH OAT room condition 260 C 50 RH The high efficiency low pressure loss total heat exchanger is made of specially treated paper to enable the unit to be as efficient as 76 during normal operation This allows system to recover both latent and s...

Страница 7: ...R74GXH56B SPW U095XH SPW UR94GXH56B SPW U125XH SPW UR124GXH56B SPW U165XH SPW UR164GXH56B SPW U185XH SPW UR184GXH56B SPW U255XH SPW UR254GXH56B SPW U365XH SPW UR364GXH56B SPW U485XH SPW UR484GXH56B SPW U605XH SPW UR604GXH56B DR Type Concealed Duct SPW DR254GXH56B SPW DR364GX H56B SPW DR484GX H56B SPW DR764GX H56B SPW DR964GX H56B K Type Wall Mounted Unit SPW K075XH SPW K095XH SPW K125XH KR Type Wa...

Страница 8: ...ON OFF Mode setting Fan speed setting Temperature setting Air flow direction Permit Prohibit switching Weekly programme 1 Setting is not possible when a remote control unit is present Use the remote control for setting Centralised control systems Operation with various function from central station Only ON OFF operation from central station Simplified charge ratio for each tenant Touch screen pane...

Страница 9: ... to present only general particulars and shall not form any part of the contract For full installation details please contact your SANYO distributor Rating Conditions The cooling and heating capacities are based on the following conditions Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB Outdoor Temperature 7 C DB 6 C WB Printed usin...