7
−
Measuring Point Measuring Equipment
Condition
Adj. Value
OSCILLOSCOPE
POWER ON
E-E Mode
1.00 V
±
0.04 V p-p
MONITOR OUT
VR105 (CP-1 board)
Adj. Location
3. ADJUSTMENT
3-1. OUTPUT SIGNAL LEVEL ADJUSTMENT
1. Input a color bar signal containing 100% white to the CH1
input terminal.
2. Select "CH1" and switch to full screen mode.
3. Connect a 75
Ω
termination to the MONITOR OUT connector
and connect an oscilloscope.
4. Use VR105 to adjust until the 100% white level from the
sync chip for the Y signal is 1.00
±
0.04 Vp-p.
Z3001
C1235
VR105
S3001
1.00
±
0.04
Vp-p