1
2
3
4
– 9 –
SM830076
1. Specifications
1-1
Unit Specifications
MODEL No.
Indoor Unit
XHS3632
Outdoor Unit
CH3632
POWER SOURCE
230 - 208 VAC / 1 Phase / 60 Hz
PERFORMANCE
Cooling
Heating
Capacity*
BTU / h
34,500
33,500
37,500
36,500
(17
°
F)**
25,000
23,500
Moisture removal (High)
Pints / h
11.1
11.1
—
Air circulation (Hi)
cu.ft. / min.
980 / 880
S.E.E.R. (H.S.P.F.)
BTU / Wh
10.7
11.0
(7.0)
(7.0)
ELECTRICAL RATINGS
Voltage rating
VAC
230
208
230
208
Available voltage range
VAC
187 - 253
187 - 253
Running amperes
A
15.4
15.8
18.2
19.3
Max. running amperes
A
—
—
—
—
Power input*
W
3,350
3,200
3,850
3,750
(17
°
F)**
3,150
2,950
Buck-up heater
kW
—
—
—
—
Maximum fuse size
A
30
FEATURES
Controls
Microprocessor
Fan speeds Indoor / Outdoor
3 and Automatic control / 2 (Auto)
Timer
ON / OFF 24-hours & Program
Air deflection
Horizontal / Vertical
— / Automatic
Air filter
Washable, easy access, long life fiter (2,500 hr)
Operation sound
Indoor
dB - A
43 / 40 / 36
Hi / Me / Lo
Outdoor - Hi
dB - A
56
Refrigerant control
Electronic Refrigerant Control Valve
REFRIGERANT PIPING
Limit of piping length
ft.
(m)
165 (50)
Limit of piping length at shipment
ft.
(m)
100 (30)
Limit of elevation difference
ft.
(m)
Outdoor unit is higher than indoor unit: 165 (50)
between the two units
Outdoor unit is lower than indoor unit: 100 (30)
Refrigerant piping
Narrow pipe
in. (mm)
3 / 8 (9.52)
Flare type
Wide pipe
in. (mm)
3 / 4 (19.05)