Special Remarks
‘‘DRY’’ ( ) Operation
How it works?
•
Once the room temperature reaches the level that was set, the unit
repeats the cycle of turning on and off automatically.
•
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between LOW
(for 20 seconds) and VERY LOW (for 10 seconds).
•
‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or
less.
Power failure
during operation
•
In the event of power failure, the unit will stop. When the power is
turned on again, the unit restarts within five minutes.
Clicking Sound
Clicking sound is
heard from the air
conditioner
•
In cooling and drying operation, any plastic parts may expand or shrink
due to a sudden temperature change. In this event, a clicking sound
may occur. This is normal, and the sound will soon disappear.
Remote Control Unit
•
The remote control unit sends the setting condition to the air
conditioner regularly at five minute intervals.
IMPORTANT
KS1852 and CL1852
Combination
•
When this unit is combined with the CL1852 outdoor unit, set the indoor
airflow to medium or high when the outdoor temperature drops below
32 °F to prevent condensation from forming at the indoor unit.
15
OI-330-15EG
oi330000
Содержание C0951
Страница 36: ...33 7 Printed circuit board POW KS095A POW KS095B for KS0951 ...
Страница 37: ...34 8 Printed circuit board POW KS125A POW KS095B for KS1251 ...
Страница 38: ...35 9 Printed circuit board POW KS1852 for KS1852 ...
Страница 39: ...36 10 Printed circuit board POW CL125 for CL0951 CL1251 and CL1852 ...
Страница 58: ...55 INSTRUCTION MANUAL KS0951 C0951 CL0951 KS1251 C1251 CL1251 KS1852 C1852 CL1852 APPENDIX ...