background image

8

USING THE REMOTE CONTROL UNIT

HOW TO INSTALL BATTERIES

1.

Slide the cover in the direction indicated by the arrow and remove 
it.

2.

Install two AAA alkaline batteries. Make sure the batteries point in 
the direction marked in the battery compartment.

3.

Use a thin object such as the tip of a pen to press the ACL button.

• The batteries last about six months, depending on how much 

you use the remote control unit. Replace the batteries when 
the remote control unit’s display fails to light, or when the 
remote control cannot be used to change the air conditioner’s 
settings.

• Use two fresh leak-proof type-AAA alkaline batteries.
• In replacing batteries, follow the instructions as mentioned in 

the sub-section “HOW TO INSTALL BATTERIES”.

• If you do not use the remote control unit more than 1 month, 

take out the batteries.

• Dispose of the used batteries at the designated location in 

compliance with the applicable local ordinances.

HOW TO USE THE REMOTE CONTROL UNIT

When using the remote control unit, always point the unit’s 
transmitter head directly at the air conditioner’s receiver.

REMOTE CONTROL UNIT INSTALLATION 
POSITION

The remote control unit may be operated either from a non-fixed 
position or from a wall-mounted position. To ensure that the air 
conditioner operates correctly, DO NOT install the remote control 
unit in the following places:

DO NOT

• In direct sunlight
• Behind a curtain or other places where it is covered
• More than 26 ft.(8 m) away from the air conditioner
• In the path of the air conditioner’s airstream
• Where it may become extremely hot or cold
• Where it may be subject to electrical or magnetic noise
• Where there is an obstacle between the remote control unit and air 

conditioner (since a check signal is sent from the remote control 
unit every 5 minutes)

MOUNTING THE REMOTE CONTROL UNIT

Before mounting the remote control unit, press the ON/OFF 
operation button at the mounting location to make sure that the air 
conditioner operates from that location. The indoor unit should make 
a beeping sound to indicate that it has received the signal.

To take out the remote control unit, pull it forward.

WHEN HOLDING THE REMOTE CONTROL UNIT

• When using the remote control unit and during air conditioner 

operation, the transmitter on the remote control unit should be 
pointed towards the receiver on the indoor unit.

• Make sure that there are no objects between the remote control 

unit and receiver which could block the signal.

ACL button

• Initially, the S/M switch is set 

to S. Leave this position.

NOTE

NOTE

Air conditioner 
(Indoor unit)

Receiver

Remote control

unit

(Transmitter 
head)

• To prevent loss of the remote control 

unit, you can connect the remote 
control unit to the mount by passing 
a string through the remote control 
unit and attachment hole.

Remote control unit mount

Mounting screws

5/32 x 5/8"

(4 x 16 mm)

(included)

Rear side

Hole

Press

Set in 
place

OI-107-8-EG

01_XHS1872_EN.fm  Page 8  Thursday, September 25, 2008  11:09 AM

Содержание 12XHS71

Страница 1: ...OI 85264181107000 INSTRUCTION MANUAL Inverter Controlled Split System Air Conditioner MODE D EMPLOI Climatiseur de type séparé contrôlé par inverseur This air conditioner uses the new refrigerant R410A Save These Instructions Conserver ce mode d emploi ...

Страница 2: ...oling and drying operation Automatic Switching between Cooling and Heating This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting Hot Start Heating System Right from the start the air is warm and comfortable This system prevents any cold blasts at the beginning while the heat pump is warm...

Страница 3: ...d electrician SAFETY INSTRUCTIONS Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual This symbol refers to a hazard or unsafe practice which can resul...

Страница 4: ... gas flows Drain Hose Moisture in the room condenses and drains off through this hose Outdoor Condensing Unit The outdoor unit contains the compressor fan motor heat exchanger coil and other electrical components INDOOR UNIT Air intakes Remote control unit Refrigerant tubes Drain hose OUTDOOR UNIT Air outlet Air outlet 4 locations NOTE REMOTE CONTROL receiver This section picks up infrared signals...

Страница 5: ...ogram Timer ON Timer OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation Displayed when setting timer Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when the time display is set to 1...

Страница 6: ...utton When you press this button use a small tipped object such as a ballpoint pen the mark will appear at the display And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly If the remote control is located near a heat source such as a space heater or in direct sunlight press the SENSOR button to switch to the sensor...

Страница 7: ... The air conditioner makes the room cooler FAN The air conditioner works only as a circulation fan NIGHT SETBACK button For details see 5 Night Setback Mode When you press this button in the HEAT DRY or COOL mode the mark appears in the display and the remote control unit will automatically adjust the set temperature to save energy Time display selector button This switches the time display betwee...

Страница 8: ...aces DO NOT In direct sunlight Behind a curtain or other places where it is covered More than 26 ft 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic noise Where there is an obstacle between the remote control unit and air conditioner since a check signal is sent from the remo...

Страница 9: ... change the settings as desired STEP 1 Press the MODE selector button and select the desired mode For heating operation For dehumidifying operation For cooling operation For fan only operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range STEP 4 Se...

Страница 10: ... switch to the fan mode STEP 2 Press the ON OFF operation button STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice or STEP 2 STEP 1 STEP 3 When the night setback mode is selected the air conditioner automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regar...

Страница 11: ...ention For several minutes after the start of heating operation the indoor fan runs at a lower speed until the indoor heat exchanger coil has warmed up sufficiently However the fan may remain stopped when the room temperature is low This is because the COLD DRAFT PREVENTION SYSTEM is in operation Sometimes the indoor unit may not get to the set fan speed such as LOW under cool operation at very lo...

Страница 12: ...that the program is not canceled When the ON timer and OFF timer are set to the same time the timer operates as if it is turned off Operation Indication 1 Press the OFF TIME setting button once The timer indication is displayed and the present OFF time is shown 2 Press the Advance Return button until AM 11 00 is displayed The timer indication blinks The time can be set in 10 minute increments Hold...

Страница 13: ...m Do Always try to keep the air filter clean Refer to CARE AND CLEANING A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed ADJUSTING THE AIRFLOW DIRECTION The vertical airflow can be adjusted by moving the flap with the remote control unit Do not move the flap with your hands Confirm that the remote con...

Страница 14: ...ow it to dry and then remount it Do not move the flap with your hands When using a footstool or the like be careful not to let it tip over Cleaning the main unit and remote control unit Wipe clean using a soft dry cloth To remove stubborn dirt moisten a cloth in warm water no hotter than 104 F wring thoroughly and then wipe INDOOR UNIT OPERATION button OPERATION lamp Cooling operation green Heatin...

Страница 15: ...wo air intake grille hinges 4 Clean the grille gently using a soft sponge or the like Then dry it with care Neutral detergent may be used to remove stubborn dirt Then rinse thoroughly with water and dry it Care After a prolonged idle period Check the indoor and outdoor unit air intakes and outlets for blockage if there is a blockage remove it Care Before a prolonged idle period Operate the fan for...

Страница 16: ...lter 1 Clean air filter to improve airflow 2 Heat source or many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling or too low for heating 5 Set the temperature lower or higher 6 Outdoor temperature is ...

Отзывы: