30
Two beeps are heard. The setting is saved and the UPS returns
to normal operation.
§
§
3
3
.
.
2
2
7
7
S
S
e
e
t
t
t
t
i
i
n
n
g
g
t
t
h
h
e
e
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
o
o
f
f
O
O
u
u
t
t
l
l
e
e
t
t
B
B
o
o
x
x
O
O
U
U
T
T
P
P
U
U
T
T
0
0
A
A
f
f
t
t
e
e
r
r
S
S
t
t
o
o
p
p
p
p
i
i
n
n
g
g
o
o
f
f
O
O
U
U
T
T
P
P
U
U
T
T
1
1
a
a
n
n
d
d
2
2
①
Check that the UPS is in the following condition.
②
Press and hold
for 3 or 4 seconds. Then release it when two beeps are heard.
③
Quickly press
(within 3 seconds) several times to set the 5 LEDs surrounded by in the figure
below to a blinking pattern such as the one in the figure.
④
Quickly press
(within 3 seconds) several times to switch to the setting value LED blinking pattern
to select for the 4 LEDs surrounded by
in the figure below.
⑤
Press and hold
for 3 or 4 seconds.
Then release it when two beeps are heard.
LEDs that blink when the “Continue power supply” setting is
selected.
Setting
Setting LED
Description
Stop power
supply
● ○ ○ ○
Stop power supply from OUTPUT0.
However, power supply stops when
§3.11 “Setting UPS Operation at
OFF” is set to “OFF”. When it
is set to “Bypass”, bypass power is
supplied.
Continue
power supply
○ ● ○ ○
Continue to supply power from
OUTPUT0.
The operation specified here is the operation of OUTPUT0 when output
from OUTPUT1 and OUTPUT2 stops for the following reasons.
• Stopped by power management software.
• Stopped by standard UPS service of operating system
• Stopped by §3.25 “Setting the Outlet Box OUTPUT1 Power Outage
Output Time” setting
• Stopped by §3.26 “Setting the Outlet Box OUTPUT2 Power Outage
Output Time” setting
However, when an OFF operation is performed with
on the front
panel or with the remote switch (Interface setting: Standalone), then
output from OUTPUT0 stops following the stopping of OUTPUT1 and
OUTPUT2 even if “Continue power supply” is selected.
This setting is enabled only when “Enabled” is selected in §3.20 “Enabling
and Disabling Output Line Control”.
Default
setting
Press
The blinking pattern changes each time you press
or
.
If you miss the LED blinking pattern you want to select, continue pressing
the button repeatedly until the LED blinking pattern is redisplayed.
Tip
Set the operation of the outlet box OUTPUT0 after OUTPUT1 and OUTPUT2 are stopped by the power management
software, or stopped by the standard UPS service of the operating system, or stopped after passage of the specified
“Outlet Box OUTPUT1 Power Outage Output Time” and “Outlet Box OUTPUT2 Power Outage Output Time”.
This setting is enabled only when “Enabled” is selected in §3.20 “Enabling and Disabling Output Line Control”.
This menu is available for 011 and 012 model.
MAIN SW on the back panel set to “ON” *1
The “Green INV.ON/STAND BY” and
the “Green OUTPUT are not blinking. *2
*1. Operation is possible regardless of whether
is ON or OFF.
*2. If these LEDs are blinking, Forced Bypass switch
may be set to “Bypass”. Set this switch to “Inverter”,
and restart the UPS.
Tip
The UPS switches to the user setting mode.
Buzzer sounds : 2 beeps
:
Either BATT.LOW or 25
blinks,
or both
BATT.LOW and 25
blink.
:
INPUT blinks.
:
LED is off.
:
LED is blinking.
Press
Hold for 3 or 4 sec.
until 2 beeps.
Hold for 3 or 4 sec.
until 2 beeps.