SY50U Excavator OMM
Maintenance
SANY
Operation and Maintenance Manual — 0120
5-17
TABLE OF
CONTENTS
INTRODUCTION
SAFETY
MACHINE
CONTROLS
MACHINE
OPERA
TION
MAINTENANCE
SPECIFICA
TIONS
OPTIONAL
EQUIPMENT
•
Check the starter. (See page
•
Check the engine valve clearance. (Contact a SANY dealer for more information.)
•
Change the hydraulic oil. (See page
•
Replace the hydraulic oil pilot filter. (See page
•
Replace the hydraulic oil return filter. (See page
•
Clean the hydraulic oil suction strainer. (See page
•
Collect hydraulic oil sample. (See page
•
Collect engine oil sample. (See page
Annually or Every 4000 Hours
•
Inspect the engine water pump. (See page
After Maintenance is Completed
Record the completion of all maintenance tasks in the maintenance log. If authorized, remove all lockout/tagout
warnings and machine-securing elements and fully activate the machine. Return the machine to operation.
Hydraulic Breaker Maintenance Interval
Hydraulic oil breaks down faster on machines equipped
with a hydraulic breaker than on machines equipped with a
bucket. Follow the steps below to set the service intervals:
•
Initial hydraulic filter maintenance must be carried out
after first 150 hours.
•
Hydraulic oil return filter must be replaced every 250
hours with a breaker operating rate above 50%.
•
Change the hydraulic oil according to the change
interval shown in the chart.