Collect a Final Drive Oil Sample
1. Obtain an oil analysis sample kit from a SANY dealer.
2. Operate the machine to normal operating temperature.
3. Park and prepare the machine for service. See “Maintenance Safety” on page 2-9.
4. Remove the final drive oil level plug. See “Check and Add Final Drive Oil” on page 5-46.
5. Insert the sample tube into the final drive and collect a sample of final drive oil. Reinstall the final drive oil
level plug.
6. Send the sample for testing in accordance with the instructions packaged with the sample kit.
Check the Final Drive Motor Mounting Fasteners
1. Prepare the machine for service. See “Maintenance
2. Remove three fasteners (1) and the final drive motor
cover (2).
NOTICE!
It is critical that all material used to collect the sample is absolutely clean. Failure to follow
this notice can cause equipment damage and contaminate the sample.